English
Language : 

BQ2084-V133 Datasheet, PDF (46/64 Pages) Texas Instruments – SBS v1.1-COMPLIANT GAS GAUGE FOR USE WITH THE bq29312
bq2084-V133
SLUS640A – JUNE 2005 – REVISED JUNE 2005
www.ti.com
EDV2
The EDV2 bit indicates that pack or cell voltage (program option) is less than the EDV2 threshold.
0 Voltage > EDV2 threshold (discharging)
1 Voltage = EDV2 threshold
SS
The SS bit indicates the seal state of the bq2084-V133.
0 The bq2084-V133 is in the unsealed state.
1 The bq2084-V133 is in the sealed state.
AFEFAIL
The AFEFAIL bit indicates that AFE communications has failed.
0 AFE communications are okay.
1 AFE communications have failed.
VDQ
The VDQ bit indicates if the present discharge cycle is valid for an FCC update.
0 Discharge cycle not valid
1 Discharge cycle valid
PF
The PF bit indicates that the bq2084-V133 PF Flag has been set. It is cleared only when the PF Flag has been
cleared.
0 bq2084-V133 PF Flag = 0x00
1 bq2084-V133 PF Flag = 0x66
CVOV
The CVOV bit indicates that a protection limit has been exceeded including Prolonged Overcurrent,
Overvoltage, or Overtemperature conditions. The bit is not latched and merely reflects the present fault status.
0 No secondary protection limits exceeded
1 A secondary protection limit exceeded
CVUV
The CVUV bit indicates that a protection limit has been exceeded including overload or overdischarge
conditions. The bit is not latched and merely reflects the present fault status.
0 No secondary protection limits exceeded
1 A secondary protection limit exceeded
VCELL4-VCELL1 (0x3c-0x3f)
These functions return the calculated individual cell voltages in mV.
DATA FLASH
General
The bq2084-V133 accesses the internal data flash during reset and when storing historical data. The data flash
stores basic configuration information for use by the bq2084-V133. The data flash must be programmed correctly
for proper bq2084-V133 operation.
46