AFE Configuration
The AFE protection limits are programmed as specified in the bq29312 data sheet.
AFE Over Load (DF 0xc5) sets the AFE overload protection threshold.
AFE Over Load Delay (DF 0xc6) sets the delay timing for overload protection.
AFE Short Circuit in Charge (DF 0xc7) sets the AFE short circuit in charge protection threshold and delay
time.
AFE Short Circuit in Discharge (DF 0xc8) sets the AFE short circuit in discharge protection threshold and
delay time.
SMBus command 0x46 can be used to string-read the AFE RAM with the AFE address 0x00 first, if the
bq2084-V133 is not sealed as indicated by bit 5 of PackStatus.
Table 11. Overcurrent Protection
NR=1
AFE OLV
AFE SCC
FAILURE
AFE SCD
GG Charge OC (set by DF 0x12a to 0x12c)
GG Discharge OC (set by DF 0x12d to 0x12f)
NR=0
FAILURE
AFE OLV
AFE SCC
AFE SCD
GG Charge OC (set by DF 0x12a to 0x12c)
GG Discharge OC (set by DF 0x12d to 0x12f)
FET STATUS
CHG on, ZVCHG off, DSG off
CHG off, ZVCHG off, DSG on
CHG on, ZVCHG off, DSG off
CHG off, ZVCHG off, DSG on
CHG on, ZVCHG off, DSG off
FET STATUS
All FETs off
All FETs off
All FETs off
All FETs off
All FETs off
CLEAR CONDITIONS
Same AFE SCD
Average Current ()< Clear Fail Current (DF 0x61/2) for
Fault Reset Time (DF 0x130), or disharge current >
discharge detection current (DF 0x115/6)
Average Current () ≥ -Clear Fail Current (DF 0x61/2) for
Fault Reset Time (DF 0x130), or charge current > charge
detection current (DF 0x113/4)
Same AFE SCC
Same AFE SCD
RRES=high
PRES=high
PRES=high
PRES=high
PRES=high
EXIT CONDITIONS
AFE Integrity Check
The bq2084-V133 checks the programming of the AFE registers at a period determined by AFE Check Time (DF
0xfb). The units of the check period are seconds unless the bq2084-V133 is in sleep mode, in which case the
period is AFE Check Time x Sleep Current Multiplier (DF 0xfd). If the data is not correct, the bq2084-V133
increments an internal counter until it reaches the AFE Fail Limit (DF 0xe4). Setting AFE Check Time to 0
disables this function.
When the internal AFE Fail counter reaches AFE Fail Limit, then the AFE bit in PF Status is set.
AFE Watchdog Fault and Clear
The bq29312 has a feature where the 32-kHz output (CLKOUT, pin 35) of the bq2084-V133 is used to drive its
internal clock. If this clock fails, a fault is declared in the AFE. See the bq29312 data sheet for further details.
The fault is cleared automatically on return of the 32-kHz input via the bq2084-V133 CLKOUT pin.
Permanent Failure Mode (SAFE Output)
The SAFE output of the bq2084-V133 provides an additional level of safety control. The active low safety output
can blow a fuse or control another switch on the basis of temperature, pack-voltage cell-voltage, CHG FET
Failure, severe cell imbalance, or an integrity check of the AFE and Data Flash configuration registers.
The bq2084-V133 can also activate the SAFE output and set the PF Flag based on the PFIN input. If this pin is
low for PFIN Time seconds ±1 s, then the PFIN bit in PF Status is set.