Electrical Characteristics (continued)
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
Δron
Difference of on-state resistance
between switches
IS(off) Off-state switch leakage current
IS(on)
II
ICC
Cic
Cio(off)
Cio(on)
On-state switch leakage current
Control input current
Supply current
Control input capacitance
Switch input/output capacitance
Switch input/output capacitance
Y
COM
TEST CONDITIONS
VI = VCC to GND,
VC = VIH
(see Figure 1 and
Figure 2)
IS = 4 mA
IS = 8 mA
VI = VCC and VO = GND, or
VI = GND and VO = VCC,
VINH = VIH (see Figure 3)
VI = VCC or GND, VINH = VIL,
VO = Open (see Figure 4)
VC = VCC or GND
VC = VCC or GND
VCC
1.1 V
1.65 V
2.3 V
2.7 V
2.7 V
2.7 V
2.7 V
2.5 V
2.5 V
2.5 V
MIN TYP(1)
2
3
4.5
9
MAX
4
1
1
1
0.1 (1)
UNIT
Ω
µA
1
0.1(1) µA
5 µA
10 µA
pF
pF
pF
Switching Characteristics
over recommended operating free-air temperature range, CL = 15 pF (unless otherwise noted) (see Figure 5)
PARAMETER
tpd (1)
ten
tdis
ten
tdis
FROM
(INPUT)
COM or Y
INH
A
TO
(OUTPUT)
Y or COM
COM or Y
COM or Y
VCC = 0.8 V
TYP
0.3
9.2
8.1
9.2
10
VCC = 1.2 V VCC = 1.5 V
0.1 V
0.1 V
MIN MAX MIN MAX
0.3
0.3
0.5 3.5 0.5 2.2
0.5 4.2 0.5 3.2
0.5 3.6 0.5 2.3
0.5 3.6 0.5 2.3
VCC = 1.8 V
0.15 V
VCC = 2.5 V
0.2 V
MIN TYP MAX MIN MAX
0.2
0.1
0.5
1 1.9 0.5 1.8
0.5 1.9 3.4 0.5 2.6
0.5 1.1 1.9 0.5 1.6
0.5 1.1
2 0.5 1.6
UNIT
ns
ns
ns
(1) The propagation delay is the calculated RC time constant of the typical on-state resistance of the switch and the specified load
capacitance, when driven by an ideal voltage source (zero output impedance).
Switching Characteristics
over recommended operating free-air temperature range, CL = 30 pF (unless otherwise noted) (see Figure 5)
PARAMETER
tpd (1)
ten
tdis
ten
tdis
FROM
(INPUT)
COM or Y
INH
A
TO
(OUTPUT)
Y or COM
COM or Y
COM or Y
VCC = 1.8 V
0.15 V
MIN TYP MAX
0.4
0.5 1.6 3.1
0.5 2.2 3.4
0.5 1.6
3
0.5 1.6
3
VCC = 2.5 V
0.2 V
MIN MAX
0.2
0.5 2.2
0.5 2.2
0.5 2.2
0.5 2.3
UNIT
ns
ns
ns