English
Language : 

DRV411_15 Datasheet, PDF (4/34 Pages) Texas Instruments – Sensor Signal Conditioning IC for Closed-Loop Magnetic Current Sensors
DRV411
SBOS693B – AUGUST 2013 – REVISED DECEMBER 2013
ELECTRICAL CHARACTERISTICS (continued)
At TA = +25°C, VDD = +2.7 V to +5.5 V, and zero output current ICOMP, unless otherwise noted.
DRV411
PARAMETER
TEST CONDITIONS
MIN
TYP
COMPENSATION COIL DRIVER, H-BRIDGE
Peak current
Voltage swing
Output common-mode
VOLTAGE REFERENCE
VREF
Reference voltage(4)
TA= –40°C to +125°C,
VICOMP1 – VICOMP2 = 4.2 VPP, VDD = 5 V
TA= –40°C to +125°C,
VICOMP1 – VICOMP2 = 2.5 VPP, VDD = 3.3 V
20-Ω load, VDD = 5 V
20-Ω load, VDD = 3.3 V
REFSEL [0,0](5), no load
REFSEL [1,0], no load
REFSEL [1,1], no load
210
125
4.2
2.5
2.495
1.647
49.6
250
150
VDD / 2
2.5
1.65
50
Reference voltage drift(4)
TA= –40°C to +125°C, REFSEL [00,10]
±5
Voltage divider gain error drift
TA= –40°C to +125°C, REFSEL [1,1]
±5
REFSEL [00,10], RGP package
±15
PSRR
Power-supply rejection ratio(4)
REFSEL [00,10], PWP package
±15
Load regulation
Load to GND or VDD,
ΔILOAD = 0 mA to 5 mA
0.15
REFOUT connected to VDD
20
ISC
Short-circuit current
REFOUT connected to GND
–18
DIGITAL INPUT/OUTPUT
Logic Inputs (GSEL, REFSEL pins)
CMOS-type levels
Input leakage current
0.01
VIH
High-level input voltage
VIL
Low-level input voltage
Logic Outputs (ERROR, OR pins)
0.7 × VDD
–0.3
VOL
Low-level output voltage
VOH
High-level output voltage
POWER SUPPLY
4-mA sink
0.3
See (6)
VDD
Specified voltage
IQ
Quiescent current
2.7
TA= –40°C to +125°C, ICOMP = 0 mA, no
excitation
VRST
Power-on reset threshold
TA= –40°C to +125°C
2.4
TEMPERATURE
Specified range
–40
Operating range
–50
www.ti.com
MAX UNIT
mA
mA
VPP
VPP
V
2.505
1.653
50.4
±50
±50
±200
±300
V
V
% of VDD
ppm/°C
ppm/°C
µV/V
µV/V
0.35 mV/mA
mA
mA
µA
VDD + 0.3
V
0.3 × VDD
V
V
V
5.5
V
6
mA
V
+125
°C
+150
°C
(4) See Typical Characteristic curves.
(5) Note that the numbers in the brackets correspond to the REFSEL number and its value. For example, in this case, REFSEL [0,0] means
that REFSEL1 = 0 and REFSEL2 = 0.
(6) OR and ERROR are open-drain outputs. No internal pull-up resistor. Output voltage depends on the external pull up resistor that is
used.
4
Submit Documentation Feedback
Product Folder Links: DRV411
Copyright © 2013, Texas Instruments Incorporated