English
Language : 

BQ29200 Datasheet, PDF (4/15 Pages) Texas Instruments – Voltage Protection with Automatic Cell Balance for 2-Series Cell Li-Ion Batteries
bq29200
bq29209
SLUSA52 – JUNE 2010
www.ti.com
ELECTRICAL CHARACTERISTICS
Typical values stated where TA = 25°C and VDD = 7.2 V.
Min/Max values stated where TA = –40°C to 110°C and VDD = 4 V to 10 V (unless otherwise noted).
PARAMETER
TEST CONDITION
MIN NOM MAX
VPROTECT
Overvoltage bq29209
detection
voltage
bq29200
4.30
4.35
VHYS
Overvoltage detection
hysteresis
200 300 400
VOA
Overvoltage detection
accuracy
TA = 25°C
–10
10
VOA_DRIFT
xDELAY
Overvoltage threshold
temperature drift
Overvoltage delay time
scale factor
TA = 0°C to 60°C
TA = –40°C to 110°C
TA = 0°C to 60°C
Note: Does not include external capacitor variation.
TA = –40°C to 110°C
Note: Does not include external capacitor variation.
–0.4
0.4
–0.6
0.6
5.5 8.0 11.0
5.0 8.0 12.5
Overvoltage delay time
xDELAY_CTM (1) scale factor in Customer
Test Mode
0.08
ICD(CHG)
Overvoltage detection
charging current
150
ICD(DSG)
Overvoltage detection
discharging current
60
Overvoltage detection
VCD
external capacitor
1.2
comparator threshold
ICC
VOUT
IOH
IOL
IOH_ZV
Supply current
(VC2–VC1) = (VC1–GND) = 3.5 V (See Figure 1)
OUT pin drive voltage
High-level output current
Low-level output current
High-level short-circuit
output current
(VC2–VC1) = (VC1–GND) = VPROTECTMAX,
VDD = VC2, IOH = 0
VC2 = VC1 = VPROTECTMAX, VDD = VC2,
IOH = –100 µA, TA = 0°C to 60°C
(VC2–VC1) and (VC1–GND) < VPROTECT,
IOL = 100 µA, TA = 25°C
(VC2–VC1) and (VC1–GND) < VPROTECT,
IOL = 0 µA, TA = 25°C
VC2 = VC1 = VDD = 4 V, IOL = 100 µA
(VC2–VC1) or (VC1–GND) > VPROTECT,
VDD = 4 V to 10 V, IOH = –100 µA
TA = –40°C to 60°C
(VC2–VC1) or (VC1–GND) > VPROTECT,
VDD = 5 V to 10 V, IOH = –100 µA
TA = 60°C to 110°C
OUT = 2 V, (VC2–VC1) = (VC1–GND) = VPROTECTMAX, VDD =
4 V to 10 V, TA = –40°C to 60°C
OUT = 2 V, (VC2–VC1) = (VC1–GND) = VPROTECTMAX, VDD =
5 V to 10 V, TA = 60°C to 110°C
OUT = 0.05 V, (VC2–VC1) = (VC1–GND) = 3.5 V,
VDD = VC2
OUT = 0V (VC2–VC1) = (VC1–GND) = VPROTECTMAX VDD = 4
to 10 V
6
2
2
–100
30
3.0
8.25
2.5
0
6.0
9.5
3
200
10
200
85
–8.0
IIN
VMM_DET_ON
Measured at VC1, (VC2–VC1) = (VC1–GND) = 3.5 V,
Input current at VCx pins TA = 0°C to 60°C (See Figure 1)
Measured at VC2, (VC2–VC1) = (VC1–GND) = 3.5 V
TA = 0°C to 60°C (See Figure 1)
Cell mismatch detection (VC2–VC1) versus (VC1–GND) and vice-versa when cell
threshold for turning ON balancing is enabled
–0.2
0.2
2.5
17 30 45
UNIT
V
mV
mV
mV°/C
s/µF
s/mF
nA
µA
V
µA
V
V
mV
mV
mV
V
µA
mA
mA
µA
µA
mV
(1) Specified by design. Not 100% tested in production.
4
Submit Documentation Feedback
Product Folder Link(s): bq29200 bq29209
Copyright © 2010, Texas Instruments Incorporated