BQ29200 Datasheet, PDF (3/15 Pages) Texas Instruments – Voltage Protection with Automatic Cell Balance for 2-Series Cell Li-Ion Batteries | |||
|
◁ |
www.ti.com
FUNCTIONAL BLOCK DIAGRAM
VC2
VC1
VC1_CB
GND
CB_EN
CB2_EN
CB
Logic
CB1_EN
CTRL
+
Hys.
-
+
-
VDD
5V LDO &
POR
ICD(CHG) =
150 nA
CD
0.1 µF
bq29200
bq29209
SLUSA52 â JUNE 2010
OUT
ABSOLUTE MAXIMUM RATINGS
Over-operating free-air temperature range (unless otherwise noted)(1)
VALUE / UNIT
Supply voltage range, VMAX
VDDâGND
VC2âGND, VC1âGND
â0.3 to 16 V
â0.3 to 16 V
Input voltage range, VIN
VC2âVC1, CDâGND
CB_ENâGND
â0.3 to 8 V
â0.3 to 16 V
Output voltage range, VOUT OUTâGND
Continuous total power dissipation, PTOT
Storage temperature range, TSTG
Lead temperature (soldering, 10 s), TSOLDER
â0.3 to 16 V
See package dissipation rating
â65°C to 150°C
300°C
(1) Stresses beyond those listed under âabsolute maximum ratingsâ may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under ârecommended operating
conditionsâ is not implied. Exposure to absoluteâmaximumârated conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Supply voltage, VDD
Input voltage range
VC2âVC1, VC1âGND
Delay time capacitance, td(CD)
CCD (See Figure 4)
Voltage monitor filter resistance RIN (See Figure 4)
Voltage monitor filter capacitance CIN (See Figure 4)
Supply voltage filter resistance RVD (See Figure 4)
Supply voltage filter capacitance CVD (See Figure 4)
Cell balance resistance
RCB (See Figure 4 and PROTECTION (OUT) TIMING)
Operating ambient temperature range, TA
MIN NOM MAX UNIT
4
10 V
0
5V
0.1
µF
100
1K
Ω
0.01
0.1
µF
100 1K Ω
0.1
µF
100
4.7K Ω
â40
110 °C
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): bq29200 bq29209
Submit Documentation Feedback
3
|
▷ |