English
Language : 

THS4032IDR Datasheet, PDF (31/47 Pages) Texas Instruments – 100-MHz LOW-NOISE HIGH-SPEED AMPLIFIERS
THS4031
THS4032
www.ti.com
SLOS224G – JULY 1999 – REVISED MARCH 2010
always be soldered to a copper plane to fully use the heat dissipation properties of the PowerPAD™. The SOIC
package, on the other hand, is highly dependent on how it is mounted on the PCB. As more trace and copper
area is placed around the device, qJA decreases and the heat dissipation capability increases. The currents and
voltages shown in these graphs are for the total package. For the dual amplifier package (THS4032), the sum of
the RMS output currents and voltages should be used to choose the proper package.
MAXIMUM RMS OUTPUT CURRENT
vs
RMS OUTPUT VOLTAGE DUE TO THERMAL LIMITS
MAXIMUM RMS OUTPUT CURRENT
vs
RMS OUTPUT VOLTAGE DUE TO THERMAL LIMITS
200
SO-8
180 qJA = 121 °C/W
High-K Test PCB
160
140
120
100
Maximum Output
Current Limit Line
Package With
qJA <= 120 °C/W
1000
TJ = 130 °C
TA = 50 °C
DGN Package
qJA = 58.4 °C/W
VCC = ±15 V
Maximum Output
Current Limit Line
100
80
SO-8
qJA = 167 °C/W
60
Low-K Test PCB
40
VCC = ±5 V
20
TJ = 130 °C
TA = 50 °C
0
0
1
2
3
4
5
|Vout| - RMS Output Voltage - V
Figure 63.
MAXIMUM RMS OUTPUT CURRENT
vs
RMS OUTPUT VOLTAGE DUE TO THERMAL LIMITS
200
Package With
180 qJA <= 60 °C/W
160
Maximum Output
Current Limit Line
SO-8 Package
qJA = 98 °C/W
SO-8 Package High-K Test PCB
qJA = 167 °C/W
Low-K Test PCB
10
0
3
6
9
12
15
|Vout| - RMS Output Voltage - V
Figure 64.
MAXIMUM RMS OUTPUT CURRENT
vs
RMS OUTPUT VOLTAGE DUE TO THERMAL LIMITS
1000
Both Channels
TJ = 130 °C
TA = 50° C
Maximum Output THS4032
Current Limits Line VCC = ±15 V
140
DGN Package
120
qJA = 58.4 °C/W
100
80
60
Safe
Operating
Area
THS4032
VCC = ±5 V
40
20
0
0
SO-8 Package
qJA = 167 °C/W
Low-K Test PCB
SO-8 Package
qJA = 98 °C/W
High-K Test PCB
Both Channels
TJ = 130 °C
TA = 50 °C
1
2
3
4
5
|Vout| - RMS Output Voltage - V
Figure 65.
100 DGN Package
qJA = 58.4 °C/W
10
1
0
SO-8 Package
qJA = 98 °C/W
High-K Test PCB
SO-8 Package
qJA = 167 °C/W
Low-K Test PCB
Safe
Operating
Area
3
6
9
12
15
|Vout| - RMS Output Voltage - V
Figure 66.
Copyright © 1999–2010, Texas Instruments Incorporated
Product Folder Link(s): THS4031 THS4032
Submit Documentation Feedback
31