English
Language : 

BQ2085 Datasheet, PDF (30/56 Pages) Texas Instruments – SBS-COMPLIANT GAS GAUGE IC FOR USE WITH THE bq29311
bq2085
SLUS541 – OCTOBER 2002
Output: Unsigned integer-percent of remaining capacity.
Units: %
Range: 0–100%
Granularity: 1%
Accuracy: -0, +MaxError( )
AbsoluteStateOfCharge( )(0x0e)
Description: Returns the predicted remaining battery capacity expressed as a percentage of
DesignCapacity( ) (%). Note that AbsoluteStateOfCharge( ) can return values greater than 100%.
Purpose: The AbsoluteStateOfCharge( ) function is used to estimate the amount of charge remaining in the
battery relative to the nominal or DesignCapacity( ).
SMBus protocol: Read word
Output: Unsigned integer—percent of remaining capacity.
Units: %
Range: 0–100+%
Granularity: 1%
Accuracy: -0, +MaxError( )
RemainingCapacity( ) (0x0f)
Description: Returns the predicted charge or energy remaining in the battery. The RemainingCapacity( ) value
is expressed in either charge or energy, depending on the setting of the BatteryMode( ) CAPACITY_MODE bit.
Purpose: The RemainingCapacity( ) function returns the battery’s remaining capacity. This information is a
numeric indication of remaining charge or energy given by the Absolute or Relative StateOfCharge( ) functions
and may be in a better form for use by power management systems.
SMBus protocol: Read word
Output: Unsigned integer—remaining charge in units of mAh or 10 mWh.
Units
Range
Granularity
Accuracy
BATTERY MODES
CAPACITY_MODE
BIT = 0
CAPACITY_MODE
BIT = 1
mAh
10 mWh
0–65,535mAh
0–65,535 10 mWh
mAh
10 mWh
–0, +MaxError( ) * FullCharageCapacity( )
FullChargeCapacity( ) (0x10)
Description: Returns the predicted pack capacity when it is fully charged. The FullChargeCapacity( ) value
is expressed in either current (mAh at a C/5 discharge rate) or power (10 mWh at a P/5 discharge rate)
depending on the setting of the BatteryMode( ) CAPACITY_MODE bit.
Purpose: The FullChargeCapacity( ) function provides a means of understanding the tank size of the battery.
This information, along with information about the original capacity of the battery, indicates battery wear.
SMBus protocol: Read word
Output: Unsigned integer—estimated full-charge capacity in units of mAh or 10 mWh.
30