English
Language : 

TS3DDR32611_15 Datasheet, PDF (3/13 Pages) Texas Instruments – 1A Peak Sink/Source PCDDR3 Termination Regulator with Integrated Isolation Switch and Low Power Mode Operation
www.ti.com
TS3DDR32611
SCDS347A – AUGUST 2013 – REVISED SEPTEMBER 2013
STATE
Power Down mode(2)
Low Speed mode
High Speed mode
VTT_EN (1)
L
H
H
FUNCTION TABLE
ODT_EN (1)
VTT
L
OFF(Discharge)
L
ON
H
ON
VREF
OFF(Discharge)
ON
ON
SWITCH
Disabled
Disabled
Enabled
(1) The VTT_EN and ODT_EN pins has 6MΩ weak pull-down resistor to GND to make its default value to be LOW.
(2) For VTT_EN= L and ODE_EN= H, the TS3DDR32611 will also stays in the power down mode. However, there will be an increased
leakage current of up to max 25µA depending on the voltage level of ODT_EN and is thus not a recommended setting to use.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)(1) (2)
VDD
VCTRL
VDDQ
VLDOIN
VTT, VREF
VTTSNS
PGND
HBM
CDM
TJ
TA
Supply voltage range(3)
Control input (VTT_EN, ODT_EN) voltage range(3)
VDDQ input voltage range(3)
VLDOIN input voltage range(3)
VTT, VREF output voltage range(3)
VTTSNS input voltage range(3)
PGND input voltage range(3)
Electrostatic discharge QSS 009-105 (JESD22-A114A)
Electrostatic discharge QSS 009-147 (JESD22-C101B.01)
Junction temperature
Operating free-air temperature
MIN MAX UNIT
–0.3
5.5 V
–0.3
5.5 V
–0.3
3.6 V
–0.3
3.6 V
–0.3
3.6 V
–0.3
3.6 V
–0.3
0.3 V
2 kV
500 V
–40
125 °C
–55
150 °C
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not implied.
(2) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum.
(3) All voltages are with respect to GND, unless otherwise specified.
PACKAGE THERMAL IMPEDANCE(1)
θJA Package thermal impedance
ZQC package
(1) The package thermal impedance is calculated in accordance with JESD 51-7.
(2) 69.2°C/W With 4 Central GND vias when layout.
TYP
101 (2)
UNIT
°C/W
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
VDD
VCTRL
VDDQ
VLDOIN
VTT, VREF
VTTSNS
PGND
Supply voltage range(1)
Control input (VTT_EN, ODT_EN) voltage range(1)
VDDQ input voltage range(1)
VLDOIN input voltage range(1)
VTT, VREF output voltage range(1)
VTTSNS input voltage range(1)
PGND input voltage range(1)
TA
Operating free-air temperature
(1) All voltages are with respect to GND, unless otherwise specified.
MIN
3.0
0
1.2
VTT+0.4
0
0
–0.1
–40
MAX
3.6
3.6
1.5
1.5
0.75
0.75
0.1
85
UNIT
V
V
V
V
V
V
V
°C
Copyright © 2013, Texas Instruments Incorporated
Product Folder Links :TS3DDR32611
Submit Documentation Feedback
3