English
Language : 

THS1050IPHP Datasheet, PDF (3/21 Pages) Texas Instruments – 10-BIT 50 MSPS IF SAMPLING COMMUNICATIONS
THS1050
10-BIT 50 MSPS IF SAMPLING COMMUNICATIONS
ANALOG-TO-DIGITAL CONVERTER
SLAS278A – APRIL 2000 – REVISED MARCH 2001
detailed description
The THS1050 uses a differential pipeline architecture and assures no missing codes over the full operating
temperature range. The device uses a 1 bit per stage architecture in order to achieve the highest possible
bandwidth. The differential analog inputs are terminated with a 900-Ω resistor. The inputs are then fed to a unity
gain buffer followed by the S/H (sample and hold) stage. This S/H stage is a switched capacitor operational
amplifier based circuit, see Figure 3. The pipeline is a typical 1 bit per stage pipeline as shown in the functional
block diagram. The digital output of the 10 stages and the last 1 bit flash are sent to a digital correction logic
block which then outputs the final 10 bits.
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage range: AVDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
DVDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
DRVDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Voltage between AVSS and DVSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 0.5 V
Voltage between DRVDD and DVDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 5 V
Voltage between AVDD and DVDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 5 V
Digital data output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to DVDD + 0.3 V
CLK peak input current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
Peak total input current (all inputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 30 mA
Operating free-air temperature range, TA: THS1050C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
THS1050I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from the case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
PARAMETER
Sample rate
Analog supply voltage, AVDD
Digital supply voltage, DVDD
Digital output driver supply voltage, DRVDD
CLK + high level input voltage, VIH
CLK + low-level input voltage, VIL
CLK – high-level input voltage, VIH
CLK – low-level input voltage, VIL
CLK pulse-width high, tp(H)
CLK pulse-width low, tp(L)
Operating free-air temperature range, TA
Operating free-air temperature range, TA
THS1050C
THS1050I
MIN NOM MAX UNIT
1
50 MSPS
4.75
5 5.25 V
4.75
5 5.25 V
3 3.3 5.25 V
4
5 5.5 V
0
1V
4
5 5.5 V
0
1V
9
10
ns
9
10
ns
0
70 °C
– 40
85 °C
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3