CD54ACT112_08 Datasheet, PDF (3/13 Pages) Texas Instruments – DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOPS WITH CLEAR AND PRESET | |||
|
◁ |
CD54ACT112, CD74ACT112
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SCHS323 â JANUARY 2003
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN MAX
â55°C to
125°C
MIN MAX
â40°C to
85°C
MIN MAX
UNIT
VOH
VI = VIH or VIL
VOL
II
ICC
DICC
VI = VIH or VIL
VI = VCC or GND
VI = VCC or GND,
VI = VCC â 2.1 V
IOH = â50 µA
IOH = â24 mA
IOH = â50 mAâ
IOH = â75 mAâ
IOL = 50 µA
IOL = 24 mA
IOL = 50 mAâ
IOL = 75 mAâ
IO = 0
4.5 V
4.5 V
5.5 V
5.5 V
4.5 V
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
4.5 V to
5.5 V
4.4
4.4
4.4
3.94
3.7
3.8
V
3.85
3.85
0.1
0.1
0.1
0.36
0.5
0.44
V
1.65
1.65
±0.1
±1
±1 µA
4
80
40 µA
2.4
3
2.8 mA
Ci
10
10
10 pF
â Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-⦠transmission-line drive capability at 85°C and 75-⦠transmission-line drive capability at 125°C.
ACT INPUT LOAD TABLE
INPUT
UNIT LOAD
J or CLK
1
K
0.53
CLR or PRE
0.58
Unit Load is âICC limit specified in
electrical characteristics table
(e.g., 2.4 mA at 25°C).
timing requirements over recommended operating conditions (unless otherwise noted)
fclock Clock frequency
tw
Pulse duration
tsu
Setup time, before CLKâ
th
Hold time, after CLKâ
trec
Recovery time, before CLKâ
CLK high or low
CLR or PRE low
J or K
J or K
CLRâ or PREâ
â55°C to
125°C
MIN MAX
100
5
5.5
4
1
2.5
â40°C to
85°C
MIN MAX
114
4.4
4.8
3.5
1
2.2
UNIT
MHz
ns
ns
ns
ns
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265