English
Language : 

BQ24610_2 Datasheet, PDF (3/33 Pages) Texas Instruments – Stand-Alone Synchronous Switch-Mode Li-Ion or Li-Polymer Battery Charger with System Power Selector and Low Iq
www.ti.com
bq24610
bq24617
SLUS892 – DECEMBER 2009
PACKAGE
QFN – RGE(1)(2)
θJP
4°C/W
PACKAGE THERMAL DATA
θJA
TA = 25°C
POWER RATING
43°C/W
2.3 W
DERATING FACTOR
ABOVE TA = 25°C
0.023 W/°C
(1) This data is based on using the JEDEC High-K board and the exposed die pad is connected to a Cu pad on the board. This is
connected to the ground plane by a 2×2 via matrix. θJA has 5% improvement by 3x3 via matrix.
(2) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
Web site at www.ti.com.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted) (1) (2) (3)
VCC, ACP, ACN, SRP, SRN, BATDRV, ACDRV, CE, STAT1, STAT2, PG
PH
Voltage range
VFB
REGN, LODRV, ACSET, TS, TTC
BTST, HIDRV with respect to GND
VREF, ISET1, ISET2
Maximum difference
voltage
ACP–ACN, SRP–SRN
TJ Junction temperature range
Tstg Storage temperature range
VALUE
–0.3 to 33
–2 to 36
–0.3 to 16
–0.3 to 7
–0.3 to 39
–0.3 to 3.6
–0.5 to 0.5
–40 to 155
–55 to 155
UNIT
V
V
V
V
V
V
V
°C
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to GND if not specified. Currents are positive into, negative out of the specified terminal. Consult Packaging
Section of the data book for thermal limitations and considerations of packages.
(3) Must have a series resistor between battery pack to VFB if Battery Pack voltage is expected to be greater than 16V. Usually the resistor
divider top resistor will take care of this.
RECOMMENDED OPERATING CONDITIONS
VCC, ACP, ACN, SRP, SRN, BATDRV, ACDRV, CE, STAT1, STAT2, PG
PH
VFB
Voltage range
REGN, LODRV, ACSET, TS, TTC
BTST, HIDRV with respect to GND
ISET1, ISET2
VREF
Maximum difference
voltage
ACP–ACN, SRP–SRN
TJ Junction temperature range
Tstg Storage temperature range
VALUE
–0.3 to 28
–2 to 30
–0.3 to 14
–0.3 to 6.5
–0.3 to 34
–0.3 to 3.3
3.3
–0.2 to 0.2
0 to 125
–55 to 155
UNIT
V
V
V
V
V
V
V
V
°C
°C
Copyright © 2009, Texas Instruments Incorporated