English
Language : 

BQ24100 Datasheet, PDF (3/26 Pages) Texas Instruments – SYNCHRONOUS SWITCHMODE, LI-ION AND LI-POL CHARGE MANAGEMENT IC WITH INTEGRATED POWERFETS
www.ti.com
bq24100, bq24103
bq24105, bq24108
bq24113, bq24115
SLUS606C – JUNE 2004 – REVISED SEPTEMBER 2005
PACKAGE DISSIPATION RATINGS
PACKAGE
RHL (1)
ΘJA
46.87°C/W
TA < 40°C
POWER RATING
1.81 W
DERATING FACTOR
ABOVE TA = 40°C
0.021 W/°C
(1) This data is based on using the JEDEC High-K board, and the exposed die pad is connected to a copper pad on the board. This is
connected to the ground plane by a 2x3 via matrix.
ABSOLUTE MAXIMUM RATINGS(1)
over operating free-air temperature range (unless otherwise noted)
Supply voltage range (with respect to VSS)
IN, VCC
STAT1, STAT2, PG, CE, CELLS, SNS, BAT
OUT
Input voltage range (with respect to VSS and PGND)
CMODE, TS, TTC
VTSB
ISET1, ISET2
Voltage difference between SNS and BAT inputs (VSNS - VBAT)
Output sink
STAT1, STAT2, PG
Output current (average)
OUT
TA
Operating free-air temperature range
TJ
Junction temperature range
Tstg
Storage temperature
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
UNIT
20 V
–0.3 V to 20 V
–0.7 V to 20 V
7V
3.6 V
3.3 V
±1 V
10 mA
2.2 A
–40°C to 85°C
–40°C to 125°C
–65°C to 150°C
300°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Supply voltage, VCC and IN (Tie together)
Operating junction temperature range, TJ
MIN
4.35 (1)
–40
NOM
MAX
16.0 (2)
125
UNIT
V
°C
(1) The IC continues to operate below Vmin, to 3.5 V, but the specifications are not tested and not guaranteed.
(2) The inherent switching noise voltage spikes should not exceed the absolute maximum rating on either the IN or OUT pins. A tight layout
minimizes switching noise.
ELECTRICAL CHARACTERISTICS
TJ = 0°C to 125°C and recommended supply voltage range (unless otherwise stated)
PARAMETER
TEST CONDITIONS
MIN
TYP
INPUT CURRENTS
VCC > VCC(min), PWM switching
10
IVCC(VCC) VCC supply current
VCC > VCC(min), PWM NOT switching
VCC > VCC(min), CE = HIGH
0°C ≤ TJ ≤ 65°C, VI(BAT) = 4.2 V,
VCC < V(SLP) or VCC > V(SLP) but not in charge
I(SLP)
Battery discharge sleep current, (SNS,
BAT, OUT, FB pins)
0°C ≤ TJ ≤ 65°C, VI(BAT) = 8.4 V,
VCC < V(SLP) or VCC > V(SLP) but not in charge
0°C ≤ TJ ≤ 65°C, VI(BAT) = 12.6 V,
VCC < V(SLP) or VCC > V(SLP) but not in charge
MAX UNIT
mA
5
315
µA
3.5
5.5
µA
7.7
3