English
Language : 

AMC1100 Datasheet, PDF (3/22 Pages) Texas Instruments – Fully-Differential Isolation Amplifier for Energy Metering
AMC1100
www.ti.com
REGULATORY INFORMATION
VDE AND IEC
Certified according to IEC 60747-5-2
File number: 40016131
SBAS562 – APRIL 2012
UL
Recognized under 1577 component recognition program
File number: E181974
IEC 60747-5-2 INSULATION CHARACTERISTICS
Over operating free-air temperature range, unless otherwise noted.
PARAMETER
TEST CONDITIONS
VIORM
VPR
Maximum working insulation voltage
Input-to-output test voltage
Qualification test: after input/output safety test subgroup
2/3 VPR = VIORM × 1.2, t = 10 s, partial discharge < 5 pC
Qualification test: method A, after environmental tests
subgroup 1, VPR = VIORM × 1.6, t = 10 s, partial discharge
< 5 pC
100% production test: method B1, VPR = VIORM × 1.875,
t = 1 s, partial discharge < 5 pC
VIOTM
VISO
RS
PD
Transient overvoltage
Insulation voltage per UL
Insulation resistance
Pollution degree
Qualification test: t = 60 s
Qualification test: VTEST = VISO, t = 60 s
100% production test: VTEST = 1.2 x VISO, t = 1 s
VIO = 500 V at TS
VALUE
1200
1140
1920
2250
4250
4250
5100
> 109
2
UNIT
VPEAK
VPEAK
VPEAK
VPEAK
VPEAK
VPEAK
VPEAK
Ω
°
IEC SAFETY LIMITING VALUES
Safety limiting intends to prevent potential damage to the isolation barrier upon failure of input or output (I/O) circuitry. I/O
circuitry failure can allow low resistance to either ground or supply and, without current limiting, dissipate sufficient power to
overheat the die and damage the isolation barrier, thus potentially leading to secondary system failures.
The safety-limiting constraint is the operating virtual junction temperature range specified in the Absolute Maximum Ratings
table. The power dissipation and junction-to-air thermal impedance of the device installed in the application hardware
determine the junction temperature. The assumed junction-to-air thermal resistance in the Thermal Information table is that of
a device installed in the JESD51-3, Low Effective Thermal Conductivity Test Board for Leaded Surface-Mount Packages and
is conservative. The power is the recommended maximum input voltage times the current. The junction temperature is then
the ambient temperature plus the power times the junction-to-air thermal resistance.
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
IS Safety input, output, or supply current
TC Maximum-case temperature
θJA = 246°C/W, VIN = 5.5 V, TJ = +150°C, TA = +25°C
10 mA
+150 °C
IEC 61000-4-5 RATINGS
PARAMETER
VIOSM Surge immunity
TEST CONDITIONS
1.2-μs or 50-μs voltage surge and 8-μs or 20-μs current surge
VALUE
±6000
UNIT
V
IEC 60664-1 RATINGS
PARAMETER
Basic isolation group
Installation classification
TEST CONDITIONS
Material group
Rated mains voltage ≤ 150 VRMS
Rated mains voltage ≤ 300 VRMS
Rated mains voltage ≤ 400 VRMS
Rated mains voltage < 600 VRMS
SPECIFICATION
II
I-IV
I-IV
I-III
I-III
Copyright © 2012, Texas Instruments Incorporated
Product Folder Link(s): AMC1100
Submit Documentation Feedback
3