English
Language : 

TLC2264 Datasheet, PDF (28/59 Pages) Texas Instruments – Advanced LinCMOS RAIL-TO-RAIL OPERATIONAL AMPLIFIERS
TLC226x, TLC226xA
Advanced LinCMOS RAIL-TO-RAIL
OPERATIONAL AMPLIFIERS
SLOS177D – FEBRUARY 1997 – REVISED MARCH 2001
TLC2264Q/M electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless
otherwise noted)
PARAMETER
VIO Input offset voltage
TEST CONDITIONS
TA†
25°C
Full range
TLC2264Q,
TLC2264M
MIN TYP MAX
300 2500
3000
TLC2264AQ,
TLC2264AM
MIN TYP MAX
300 950
1500
UNIT
µV
αVIO
Temperature coefficient of
input offset voltage
Input offset voltage
long-term drift (see Note 4)
VIC = 0,
RS = 50 Ω
IIO
Input offset current
IIB
Input bias current
VO = 0,
VICR
Common-mode input
voltage range
RS = 50 Ω,
|VIO| ≤ 5 mV
Full range
2
2
µV/°C
25°C
0.003
25°C
125°C
25°C
125°C
25°C
0.5
1
– 5 – 5.3
to 4 to 4.2
–5
Full range to 3.5
0.003
0.5
800
1
800
– 5 – 5.3
to 4 to 4.2
–5
to 3.5
µV/mo
pA
800
pA
800
V
VOM +
Maximum positive peak
output voltage
IO = – 20 µA
IO = – 100 µA
IO = – 400 µA
25°C
4.99
4.99
25°C
4.85 4.94
4.85 4.94
Full range 4.82
4.82
V
25°C
4.7 4.85
4.7 4.85
Full range 4.5
4.5
VIC = 0,
IO = 50 µA
25°C
– 4.99
– 4.99
25°C – 4.85 – 4.91
– 4.85 – 4.91
VOM –
Maximum negative peak
output voltage
VIC = 0,
IO = 500 µA Full range – 4.85
– 4.85
V
VIC = 0,
m IO = 4 A
25°C
Full range
– 4 – 4.3
– 3.8
– 4 – 4.3
– 3.8
AVD
Large-signal differential
voltage amplification
VO = ± 4 V
ri(d) Differential input resistance
ri(c)
Common-mode input
resistance
RL = 50 kΩ
RL = 1 MΩ
25°C
Full range
25°C
25°C
25°C
80 200
50
1000
1012
1012
80 200
50
1000
1012
1012
V/mV
Ω
Ω
ci(c)
Common-mode input
capacitance
f = 10 kHz,
N package
25°C
8
8
pF
zo
Closed-loop output
impedance
f = 100 kHz, AV = 10
25°C
220
220
Ω
CMRR
Common-mode
rejection ratio
VIC = – 5 V to 2.7 V,
25°C
75
88
VO = 0,
RS = 50 Ω Full range
75
75
88
dB
75
kSVR
Supply-voltage rejection
ratio (∆VDD ± /∆VIO)
VDD± = ± 2.2 V to ± 8 V,
VIC = VDD /2, No load
25°C
80
95
Full range
80
80
95
dB
80
Supply current
IDD (four amplifiers)
VO = 0,
No load
25°C
Full range
0.85
1
1
0.85
1
mA
1
† Full range is – 40°C to 125°C for Q suffix, – 55°C to 125°C for M suffix.
NOTE 4: Typical values are based on the input offset voltage shift observed through 500 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
28
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265