English
Language : 

TLC2264 Datasheet, PDF (10/59 Pages) Texas Instruments – Advanced LinCMOS RAIL-TO-RAIL OPERATIONAL AMPLIFIERS
TLC226x, TLC226xA
Advanced LinCMOS RAIL-TO-RAIL
OPERATIONAL AMPLIFIERS
SLOS177D – FEBRUARY 1997 – REVISED MARCH 2001
TLC2264C electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2264C
UNIT
MIN TYP MAX
VIO Input offset voltage
25°C
Full range
300 2500
µV
3000
αVIO Temperature coefficient of input offset voltage
25°C
to 70°C
2
µV/°C
Input offset voltage long-term drift
(see Note 4)
IIO
Input offset current
VIC = 0,
VO = 0,
VDD ± = ± 2.5 V,
RS = 50 Ω
25°C
25°C
Full range
0.003
0.5
µV/mo
pA
100
IIB
Input bias current
25°C
Full range
1
pA
100
0 – 0.3
25°C
to
to
VICR Common-mode input voltage range
RS = 50 Ω,
|VIO| ≤ 5 mV
4 4.2
V
0
Full range
to
3.5
VOH High-level output voltage
IOH = – 20 µA
IOH = – 100 µA
IOH = – 400 µA
25°C
4.99
25°C
4.85 4.94
Full range 4.82
V
25°C
4.70 4.85
Full range 4.60
VIC = 2.5 V,
VIC = 2.5 V,
IOL = 50 µA
IOL = 500 µA
25°C
25°C
Full range
0.01
0.09 0.15
0.15
VOL Low-level output voltage
VIC = 2.5 V,
m IOL = 1 A
25°C
Full range
0.2 0.3 V
0.3
VIC = 2.5 V,
m IOL = 4 A
25°C
Full range
0.7
1
1.2
AVD Large-signal differential voltage amplification
ri(d) Differential input resistance
ri(c) Common-mode input resistance
ci(c) Common-mode input capacitance
zo
Closed-loop output impedance
CMRR Common-mode rejection ratio
VIC = 2.5 V,
VO = 1 V to 4 V
RL = 50 kه
RL = 1 Mه
f = 10 kHz,
f = 100 kHz,
VIC = 0 to 2.7 V,
RS = 50 Ω
N package
AV = 10
VO = 2.5 V,
25°C
Full range
25°C
25°C
25°C
25°C
25°C
25°C
Full range
80 170
55
550
1012
1012
8
240
70
83
70
V/mV
Ω
Ω
pF
Ω
dB
kSVR Supply-voltage rejection ratio (∆VDD /∆VIO)
VDD = 4.4 V to 16 V,
VIC = VDD /2, No load
25°C
80
95
Full range
80
dB
IDD Supply current (four amplifiers)
VO = 2.5 V,
No load
25°C
Full range
0.8
1
mA
1
† Full range is 0°C to 70°C.
‡ Referenced to 2.5 V
NOTE 4. Typical values are based on the input offset voltage shift observed through 500 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
10
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265