English
Language : 

MSP430F2101 Datasheet, PDF (21/53 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430x21x1
MIXED SIGNAL MICROCONTROLLER
SLAS439C − SEPTEMBER 2004 − REVISED JULY 2006
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (continued)
main DCO characteristics
D All ranges selected by RSELx overlap with RSELx + 1: RSELx = 0 overlaps RSELx = 1, ... RSELx = 14
overlaps RSELx = 15.
D DCO control bits DCOx have a step size as defined by parameter SDCO.
D Modulation control bits MODx select how often fDCO(RSEL,DCO+1) is used within the period of 32 DCOCLK
cycles. The frequency fDCO(RSEL,DCO) is used for the remaining cycles. The frequency is an average equal
to:
faverage + MOD
32
fDCO(RSEL,DCO)
fDCO(RSEL,DCO)1)
fDCO(RSEL,DCO))(32*MOD) fDCO(RSEL,DCO)1)
DCO frequency
PARAMETER
TEST CONDITIONS
RSELx < 14
Vcc
Supply voltage range
RSELx = 14
RSELx = 15
fDCO(0,0)
fDCO(0,3)
fDCO(1,3)
fDCO(2,3)
fDCO(3,3)
fDCO(4,3)
fDCO(5,3)
fDCO(6,3)
fDCO(7,3)
fDCO(8,3)
fDCO(9,3)
fDCO(10,3)
fDCO(11,3)
fDCO(12,3)
fDCO(13,3)
fDCO(14,3)
fDCO(15,3)
fDCO(15,7)
SRSEL
DCO frequency (0, 0)
DCO frequency (0, 3)
DCO frequency (1, 3)
DCO frequency (2, 3)
DCO frequency (3, 3)
DCO frequency (4, 3)
DCO frequency (5, 3)
DCO frequency (6, 3)
DCO frequency (7, 3)
DCO frequency (8, 3)
DCO frequency (9, 3)
DCO frequency (10, 3)
DCO frequency (11, 3)
DCO frequency (12, 3)
DCO frequency (13, 3)
DCO frequency (14, 3)
DCO frequency (15, 3)
DCO frequency (15, 7)
Frequency step between
range RSEL and RSEL+1
RSELx = 0, DCOx = 0, MODx = 0
RSELx = 0, DCOx = 3, MODx = 0
RSELx = 1, DCOx = 3, MODx = 0
RSELx = 2, DCOx = 3, MODx = 0
RSELx = 3, DCOx = 3, MODx = 0
RSELx = 4, DCOx = 3, MODx = 0
RSELx = 5, DCOx = 3, MODx = 0
RSELx = 6, DCOx = 3, MODx = 0
RSELx = 7, DCOx = 3, MODx = 0
RSELx = 8, DCOx = 3, MODx = 0
RSELx = 9, DCOx = 3, MODx = 0
RSELx = 10, DCOx = 3, MODx = 0
RSELx = 11, DCOx = 3, MODx = 0
RSELx = 12, DCOx = 3, MODx = 0
RSELx = 13, DCOx = 3, MODx = 0
RSELx = 14, DCOx = 3, MODx = 0
RSELx = 15, DCOx = 3, MODx = 0
RSELx = 15, DCOx = 7, MODx = 0
SRSEL =
fDCO(RSEL+1,DCO)/fDCO(RSEL,DCO)
SDCO
Frequency step between SDCO =
tap DCO and DCO+1
fDCO(RSEL,DCO+1)/fDCO(RSEL,DCO)
Duty Cycle
Measured at P1.4/SMCLK
VCC
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
3V
3V
2.2 V/3 V
2.2 V/3 V
2.2 V/3 V
MIN TYP
1.8
2.2
3.0
0.06
0.07
0.10
0.14
0.20
0.28
0.39
0.54
0.80
1.10
1.60
2.50
3.00
4.30
6.00
8.60
12.0
16.0
MAX
3.6
3.6
3.6
0.14
0.17
0.20
0.28
0.40
0.54
0.77
1.06
1.50
2.10
3.00
4.30
5.50
7.30
9.60
13.9
18.5
26.0
UNIT
V
V
V
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
1.55
ratio
1.05 1.08 1.12
40
50
60 %
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265