English
Language : 

MSP430AFE2X3 Datasheet, PDF (21/47 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
www.ti.com
MSP430AFE2x3
MSP430AFE2x2
MSP430AFE2x1
SLAS701A – NOVEMBER 2010 – REVISED MARCH 2011
POR/Brownout Reset (BOR)(1) (2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
VCC(start)
V(B_IT-)
Vhys(B_IT-)
td(BOR)
t(reset)
PARAMETER
TEST CONDITIONS
See Figure 9
See Figure 9 through Figure 11
See Figure 9
See Figure 9
Pulse length needed at RST/NMI pin
to accepted reset internally
dVCC/dt ≤ 3 V/s
dVCC/dt ≤ 3 V/s
dVCC/dt ≤ 3 V/s
VCC
MIN
TYP
0.7 ×
V(B_IT-)
1.42
120
2000
3V
2
MAX UNIT
V
V
mV
µs
µs
(1) The current consumption of the brownout module is already included in the ICC current consumption data. The voltage level V(B_IT-) +
Vhys(B_IT-
) is ≤ 1.8 V.
(2) During power up, the CPU begins code execution following a period of td(BOR) after VCC = V(B_IT-) + Vhys(B_IT-). The default DCO settings
must not be changed until VCC ≥ VCC(min), where VCC(min) is the minimum supply voltage for the desired operating frequency.
VCC
Vhys(B_IT−)
V(B_IT−)
VCC(s t ar t )
1
0
t d(BOR)
Figure 9. POR/Brownout Reset (BOR) vs Supply Voltage
Copyright © 2010–2011, Texas Instruments Incorporated
Submit Documentation Feedback
21