English
Language : 

THS4631 Datasheet, PDF (2/27 Pages) Texas Instruments – HIGH-VOLTAGE, HIGH SLEW RATE, WIDEBAND FET-INPUT OPERATIONAL AMPLIFIER
THS4631
SLOS451A – DECEMBER 2004 – REVISED MARCH 2005
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated
circuits be handled with appropriate precautions. Failure to observe proper handling and installation
procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision
integrated circuits may be more susceptible to damage because very small parametric changes could
cause the device not to meet its published specifications.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)(1)
VS
Supply voltage, VS– to VS+
VI
Input voltage
IO (2)
Output current
Continuous power dissipation
TJ
Maximum junction temperature(2)
TA
Operating free-air temperature, continues operation, long-term reliability(2)
Tstg
Storage temperature range
Lead temperature
1,6 mm (1/16 inch) from case for 10 seconds
HBM
ESD ratings:
CDM
MM
UNITS
33 V
±VS
150 mA
See Dissipation Rating Table
150°C
125°C
65°C to 150°C
300°C
1000 V
1500 V
100 V
(1) The absolute maximum ratings under any condition is limited by the constraints of the silicon process. Stresses above these ratings may
cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are
stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied.
(2) The maximum junction temperature for continuous operation is limited by package constraints. Operation above this temperature may
result in reduced reliability and/or lifetime of the device.
PACKAGE DISSIPATION RATINGS
PACKAGE
D (8)(2)
DDA (8)
DGN (8)
θJC (°C/W)
38.3
9.2
4.7
θJA (°C/W)
95
45.8
58.4
POWER RATING(1) (TJ =125°C)
TA ≤ 25°C
TA = 85°C
1.1 W
0.47 W
2.3 W
0.98 W
2.14 W
1.11 W
(1) Power rating is determined with a junction temperature of 125°C. This is the point where distortion starts to substantially increase.
Thermal management of the final PCB should strive to keep the junction temperature at or below 125°C for best performance.
(2) This data was taken using the JEDEC standard High-K test PCB.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
VS
Supply Voltage
Dual Supply
Single Supply
TA
Operating free-air temperature
MIN
MAX UNITS
±5
±15
V
10
30
-40
85
°C
2