English
Language : 

BQ24072 Datasheet, PDF (19/38 Pages) Texas Instruments – 1.2A USB-FRIENDLY Li-Ion BATTERY CHARGER AND POWER-PATH MANAGEMENT IC
bq24072, bq24073
bq24074, bq24075
www.ti.com...................................................................................................................................... SLUS810A – SEPTEMBER 2008 – REVISED DECEMBER 2008
Input DPM Mode (VIN-DPM)
The bq2407x utilizes the VIN-DPM mode for operation from current-limited USB ports. When EN1 and EN2 are
configured for USB100 (EN2=0, EN1=0) or USB500 (EN2=0, EN2=1) modes, the input voltage is monitored. If
VIN falls to VIN-DPM, the input current limit is reduced to prevent the input voltage from falling further. This prevents
the bq2407x from crashing poorly designed or incorrectly configured USB sources. Figure 36 shows the VIN-DPM
behavior to a current limited source. In this figure, the input source has a 400mA current limit and the device is in
USB500 mode (EN1=1, EN2=0).
IOUT
VIN
(5V)
USB500 Current Limit
Input collapses
Input regulated to VIN_DPM
IIN
Input current limit is
reduced to prevent
crashing the supply
IBAT
200mA/div
500mV/div
200mA/div
200mA/div
4 ms/div
Figure 36. VIN-DPM Waveform
DPPM Mode
When the sum of the charging and system load currents exceeds the maximum input current (programmed with
EN1, EN2 and ILIM pins), the voltage at OUT decreases. Once the voltage on the OUT pin falls to VDPPM, the
bq2407x enters DPPM mode. In this mode, the charging current is reduced as the OUT current increases in
order to maintain the system output. Battery termination is disabled while in DPPM mode.
Battery Supplement Mode
While in DPPM mode, if the charging current falls to zero and the system load current increases beyond the
programmed input current limit, the voltage at OUT reduces further. When the OUT voltage drops below the
VBSUP1 threshold, the battery supplements the system load. The battery stops supplementing the system load
when the voltage at OUT rises above the VBSUP2 threshold.
During supplement mode, the battery supplement current is not regulated (BAT-FET is fully on), however there is
a short circuit protection circuit built in. Figure 5 demonstrates supplement mode. If during battery supplement
mode, the voltage at OUT drops VO(SC2) below the BAT voltage, the OUT output is turned off if the overload
exists after tDGL(SC2). The short circuit recovery timer then starts counting. After tREC(SC2), OUT turns on and
attempts to restart. If the short circuit remains, OUT is turned off and the counter restarts. Battery termination is
disabled while in supplement mode.
Copyright © 2008, Texas Instruments Incorporated
Submit Documentation Feedback
19
Product Folder Link(s): bq24072 bq24073 bq24074 bq24075