TLE2021 electrical characteristics at specified free-air temperature, VCC = ± 15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLE2021I
MIN TYP MAX
TLE2021AI
MIN TYP MAX
TLE2021BI
UNIT
MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
120 500
850
80 200
500
40 100
µV
200
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
2
µV/°C
Input offset voltage long-term drift
(see Note 4)
VIC = 0, RS = 50 Ω 25°C
0.006
0.006
0.006
µV/mo
IIO
Input offset current
25°C
Full range
0.2
6
10
0.2
6
10
0.2
6
nA
10
IIB
Input bias current
25°C
Full range
25
70
90
25
70
90
25
70
nA
90
– 15 – 15.3
– 15 – 15.3
– 15 – 15.3
25°C
to
to
to
to
to
to
VICR Common-mode input voltage range
RS = 50 Ω
13.5
14
13.5
14
13.5
14
V
– 15
15
15
Full range
to
to
to
3.2
3.2
3.2
VOM +
Maximum positive peak output
voltage swing
VOM –
Maximum negative peak output
voltage swing
25°C
14 14.3
14 14.3
14 14.3
V
Full range 13.9
13.9
13.9
RL = 10 kΩ
25°C – 13.7 – 14.1
– 13.7 – 14.1
– 13.7 – 14.1
V
Full range – 13.6
– 13.6
– 13.6
AVD
Large-signal differential
voltage amplification
VO = 10 V,
RL = 10 kΩ
25°C
1 6.5
Full range 0.75
1 6.5
0.75
1 6.5
0.75
V/µV
CMRR Common-mode rejection ratio
VIC = VICR min,
RS = 50 Ω
25°C
100 115
Full range
96
100 115
96
100 115
96
dB
kSVR
Supply-voltage rejection ratio
(∆VCC /∆VIO)
VCC ± = ± 2. 5 V
to ± 15 V
25°C
105 120
Full range 100
105 120
100
105 120
100
dB
ICC
∆ICC
Supply current
Supply-current change over
operating temperature range
VO = 0 V, No load
25°C
Full range
Full range
200 300
300
7
200 300
300
7
200 300
µA
300
7
µA
† Full range is – 40°C to 85°C.