4.11.2 Wake-Up Sequence
VBAT and VIO
CC3100MOD
SWRS161 – DECEMBER 2014
nRESET
nHIB
ITEM
T1
T2
T3
STATE
RESET
tT1t
HW INIT
tT2t
FW INIT
tT3t
Device ready to
serve API calls
Figure 4-7. Wake-Up Sequence
Table 4-1. First-Time Power-Up and Reset Removal Timing Requirements (32K XTAL)
NAME
Supply settling time
Hardware wakeup
time
Initialization time
DESCRIPTION
MIN
Depends on application board power supply, decap, and
so on
32-kHz XTAL settling + firmware initialization time +
radio calibration
TYP
3 ms
25 ms
1.35 s
MAX
Copyright © 2014, Texas Instruments Incorporated
Submit Documentation Feedback
Specifications
17