www.ti.com
S-Parameter, Slew Rate, Transient Response,
Settling Time, Output Voltage
The circuit shown in Figure 31 is used to measure
s-parameters, slew rate, transient response, settling
time, and output voltage swing.
Because S21 is measured single-ended at the load
with 50-Ω double termination, add 12 dB to see the
amplifier’s output as a differential signal.
From VIN
50 Ω
Source
RG
R IT
0.22 mF
49.9 W
RG
R IT
RF
VS+
THS4520
CM
VS−
RF
49.9 W
49.9 W
Open
0.22 mF
VOUT+ To 50 W
Test
VOUT− Equipment
Figure 31. S-Parameter, SR, Transient Response,
Settling Time, VOUT Swing
THS4520
SLOS503A – SEPTEMBER 2006 – REVISED OCTOBER 2006
CM Input
The circuit shown in Figure 32 is used to measure
the frequency response of the CM input. Frequency
response is measured single-ended at VOUT+ or
VOUT– with the input injected at VIN, RCM = 0 Ω and
RCMT = 49.9 Ω.
0.22 mF
49.9 W
0.22 mF
49.9 W
RG
RIT
RG
RIT
RF
VS+
49.9 W
THS4520 49.9 W
CM
VS–
RF
RCM
RCMT
To
VOUT– 50-W
Test
VOUT+ Equipment
VIN From
50-W
Source
Figure 32. CM Input Test Circuit
Submit Documentation Feedback
15