English
Language : 

BQ27541 Datasheet, PDF (15/38 Pages) Texas Instruments – Single Cell Li-Ion Battery Fuel Gauge for Battery Pack Integration
bq27541
www.ti.com ........................................................................................................................................................................................... SLUS861 – DECEMBER 2008
MaxLoadTimeToEmpty( ): 0x20/0x21
This read-only function returns an unsigned integer value of the predicted remaining battery life at the maximum
load current discharge rate, in minutes. A value of 65,535 indicates that the battery is not being discharged.
AvailableEnergy( ): 0x22/0x23
This read-only function returns an unsigned integer value of the predicted charge or energy remaining in the
battery. The value is reported in units of mWh.
AveragePower( ): 0x24/0x25
This read-word function returns an unsigned integer value of the average power of the current discharge. A value
of 0 indicates that the battery is not being discharged. The value is reported in units of mW.
TimeToEmptyAtConstantPower( ): 0x26/0x27
This read-only function returns an unsigned integer value of the predicted remaining operating time if the battery
is discharged at the AveragePower( ) value in minutes. A value of 65,535 indicates AveragePower( ) = 0. The
fuel gauge automatically updates TimeToEmptyatContantPower( ) based on the AveragePower( ) value every 1s.
CycleCount( ): 0x2a/0x2b
This read-only function returns an unsigned integer value of the number of cycles the battery has experienced
with a range of 0 to 65,535. One cycle occurs when accumulated discharge ≥ CC Threshold.
StateOfCharge( ): 0x2c/0x2d
This read-only function returns an unsigned integer value of the predicted remaining battery capacity expressed
as a percentage of FullChargeCapacity( ), with a range of 0 to 100%.
Copyright © 2008, Texas Instruments Incorporated
Product Folder Link(s): bq27541
Submit Documentation Feedback
15