English
Language : 

TLE2161 Datasheet, PDF (10/29 Pages) Texas Instruments – EXCALIBUR JFET-INPUT HIGH-OUTPUT-DRIVE mPOWER OPERATIONAL AMPLIFIERS
TLE2161, TLE2161A, TLE2161B
EXCALIBUR JFET-INPUT HIGH-OUTPUT-DRIVE
µPOWER OPERATIONAL AMPLIFIERS
SLOS049D – NOVEMBER 1989 – REVISED MAY 1996
electrical characteristics at specified free-air temperature, VCC ± = ± 15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLE2161I, TLE2161AI
TA†
TLE2161BI
UNIT
MIN TYP MAX
TLE2161I
25°C
Full range
0.6
3
4.3
VIO
Input offset voltage
TLE2161AI
25°C
Full range
0.5 1.5
mV
2.9
αVIO
IIO
TLE2161BI
Temperature coefficient of input offset voltage
Input offset voltage long-term drift (see Note 4)
Input offset current
VIC = 0,
RS = 50 Ω
25°C
Full range
Full range
25°C
25°C
Full range
0.3 0.5
1.3
6
µV/°C
0.04
µV/mo
2
pA
3 nA
IIB
Input bias current
25°C
Full range
4
pA
5 nA
VICR Common-mode input voltage range
– 11 – 12
25°C
to
to
V
13
16
– 11
Full range
to
V
13
VOM + Maximum positive peak output voltage swing
RL = 10 kΩ
RL = 600 Ω
25°C
13.2 13.7
Full range
13
V
25°C
12.5 13.2
Full range
12
VOM – Maximum negative peak output voltage swing
RL = 10 kΩ
RL = 600 Ω
25°C – 13.2 – 13.7
Full range – 13
V
25°C – 12.5 – 13
Full range – 12
V0 = ± 10 V,
RL = 10 kΩ
25°C
Full range
30 230
20
AVD Large-signal differential voltage amplification
25°C
V0 = 0 to 8 V, RL = 600 Ω Full range
25 100
10
V/mV
ri
Input resistance
ci
Input capacitance
zo
Open-loop output impedance
CMRR Common-mode rejection ratio
25°C
V0 = 0 to – 8 V, RL = 600 Ω Full range
3
25
1
25°C
1012
Ω
25°C
4
pF
IO = 0
25°C
280
Ω
25°C
72
90
VIC=VICRmin, RS = 50 Ω Full range
65
dB
kSVR Supply-voltage rejection ratio (∆VCC± /∆VIO)
VCC± = ± 5 V to ± 15 V,
RS = 50 Ω
25°C
75
93
Full range
65
dB
ICC
∆ICC
Supply current
Supply-current change over operating
temperature range
VO = 0,
No load
25°C
Full range
Full range
290 350
µA
375
34
µA
† Full range is – 40°C to 85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA= 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
10
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265