U2784B Datasheet, PDF (4/11 Pages) TEMIC Semiconductors – 2200 MHz / 200 MHz Twin PLL
U2784B
Serial Programming Bus
Reference and programmable counters can be
programmed by the 3-wire-bus (Clock, Data and Enable).
After setting enable signal to high condition, the data
status is transfered bit by bit on the rising edge of the clock
signal into the shift register, starting with the MSB-bit.
After the Enable signal returns to low condition the
programmed information is loaded according to the
addressbits (last three bits) into the addressed latch.
Additional leading bits are ignored and there is no check
made the 3-wire-bus remains active and the IC can be
programmed.
Data is entered with the most significant bit first. The
leading bits deliver the divider or control information.
The trailing three bits are the address field. There are six
different addresses used. The trailing address bits are
decoded upon the falling edge of the Enable signal. the
internal Loadpulse is beginning with the falling edge of
the Enable signal and ending with the falling edge of the
Clock signal. Therefore a minimum holdtime
clock-enable tHCE is required.
Bit Allocation
MSB
LSB
Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
data bits
address bits
D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 A2 A1 A0
PLL1
PLL1
M10 M9 M8 M7 M6 M5 M4 M3 M2 M1 M0 S5 S4 S3 S2 S1 S0 0 0 1
PLL1
PLL1
R11 R10 R9 R8 R7 R6 R5 R4 R3 R2 R1 R0 0 1 0
PLL2
PLL2
M10 M9 M8 M7 M6 M5 M4 M3 M2 M1 M0 S2 S1 S0 0 1 1
PLL2
PLL2
R11 R10 R9 R8 R7 R6 R5 R4 R3 R2 R1 R0 1 0 0
RF/ Test 5IP TRI TRI PS2 PS1 H2P H1P LP LPA P4 P3 P2 P1 P0 1 0 1
2
21
B
SP SP SP
D 5I D 2 D 1 1 1 0
Scaling Factors
PGD of PLL1:
S0 ... S5:
M0 ... M10:
SPGD:
These bits are setting the swallow counter SS.
SS = S0*20 + S1*21 + ... + S4*24 + S5*25
allowed scalling factors for SS: 0 ... 63, SS < SM
These bits are setting the main counter SM.
SM = M0*20 + M1*21 + ... + M9*29 + M10*210
allowed scalling factors for SM: 5 ... 2047
Total scalling factor of the programmable counter:
SPGD = (64*SM) + SS Condition: SS < SM
RFD of PLL1 and PLL2:
R0 ... R11:
RF/2 = 1:
RF/2 = 0:
These bits are setting the reference counter SR.
SR = R0*20 + ... + R10*210 + R11*211
allowed scalling factors for SR: 5 ... 4095
SRFD = 2 * SR
SRFD = SR
PGD of PLL2:
S0 ... S4:
M0 ... M9:
SPGD:
These bits are setting the swallow counter SS.
SS = S0*20 + S1*21 + S2*22
allowed scalling factors for SS: 0 ... 7, SS < SM
These bits are setting the main counter SM.
SM = M0*20 + M1*21 + ... + M9*29 + M10*210
allowed scalling factors for SM: 5 ... 2047
Total scalling factor of the programmable counter:
SPGD = (8*SM) + SS Condition: SS < SM