English
Language : 

DG401 Datasheet, PDF (4/10 Pages) Intersil Corporation – Monolithic CMOS Analog Switches
DG401/403/405
Specificationsa
Parameter
Analog Switch
Analog Signal Rangee
Drain-Source
On-Resistance
D Drain-Source
On-Resistance
Switch Off
Leakage Current
Channel On
Leakage Current
Digital Control
Input Current VIN Low
Symbol
VANALOG
rDS(on)
DrDS(on)
IS(off)
ID(off)
ID(on)
IIL
Input Current VIN High
IIH
Dynamic Characteristics
Turn-On Time
tON
Turn-Off Time
tOFF
Break-Before-Make
Time Delay (DG403)
tD
Charge Injection
Q
Off Isolation Reject Ratio
Channel-to-Channel Cross-
talk
Source Off Capacitance
Drain Off Capacitance
Channel On Capacitance
Power Supplies
OIRR
XTALK
CS(off)
CD(off)
CD, CS(on)
Positive Supply Current
I+
Negative Supply Current
I–
Logic Supply Current
Ground Current
IL
IGND
Test Conditions
Unless Specified
V+ = 15 V, V– = –15 V
VL = 5 V, VIN = 2.4 V, 0.8 Vf
Tempb
IS = –10 mA, VD = "10 V
V+ = 13.5 V, V– = –13.5 V
IS = –10 mA, VD = "5 V, 0 V
V+ = 16.5 V, V– = –16.5 V
V+ = 16.5, V– = –16.5 V
VD = "15.5 V, VS = #15.5 V
V+ = 16.5 V, V– = –16.5 V
VS = VD = "15.5 V
Full
Room
Full
Room
Full
Room
Hot
Room
Hot
Room
Hot
VIN under test = 0.8 V
All Other = 2.4 V
Full
VIN under test = 2.4 V
All Other = 0.8 V
Full
RL = 300 W , CL = 35 pF
See Figure 2
RL = 300 W , CL = 35 pF
CL = 10,000 pF
Vgen = 0 V, Rgen = 0 W
RL = 100 W , CL = 5 pF
f = 1 MHz
f = 1 MHz, VS = 0 V
Room
Room
Room
Room
Room
Room
Room
Room
Room
V+ = 16.5 V, V– = –16.5 V
VIN = 0 or 5 V
Room
Full
Room
Full
Room
Full
Room
Full
Typc
20
3
–0.01
–0.01
–0.04
0.005
0.005
100
60
12
60
72
90
12
12
39
0.01
–0.01
0.01
–0.01
A Suffix
–55 to 125_C
D Suffix
–40 to 85_C
Mind Maxd Mind Maxd Unit
–15 15 –15 15 V
35
45
45
55
W
3
3
5
5
–0.25 0.25 –0.5 0.5
–20 20
–5
5
–0.25 0.25 –0.5 0.5
–20 20
–5
5
nA
–0.4 0.4 –1
1
–40 40 –10 10
–1
1
–1
1
mA
–1
1
–1
1
150
150
100
100 ns
5
5
pC
dB
pF
1
1
5
5
–1
–1
–5
–5
mA
1
1
5
5
–1
–1
–5
–5
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
4
Siliconix
S-53748—Rev. E, 05-Jun-97