English
Language : 

DRL48R35 Datasheet, PDF (3/4 Pages) Teledyne Technologies Incorporated – Single Output to 35A 510 Vac DIN-Rail Solid-State Relay
Series DRL
OUTPUT (LOAD) SPECIFICATION
Min
Max
Operating Range
24
510
Peak Voltage
1200
Unit
Vrms
Vpeak
Clamping Voltage
-21 feature (On voltage, typical) 950
V
All others (@1mA)
820
V
ENVIRONMENTAL SPECIFICATION
Min
Max
Storage Temperature
–30
100
Operating Temperature
–30
80
Input-Output Isolation
4000
Output-Case Isolation
4000
Insulation Resistance
100
Rated Impulse Voltage
4000
Unit
°C
°C
Vrms
Vrms
MΩ
V
Zero-Cross Window (Typical)
DRL48R35
DRL48D35-21
DRL48D35
DRL48A
Random
±10
V
±20
V
±20
V
Non-Repetitive Surge Current
(See Figure 5)
550
A
On-State Voltage Drop (Typical)
0.9 V
Output Power Dissipation
(Typical)
0.81xIe+0.08xIe2
Thermal Resistance
(Junction to Air)
2.6 °C/W
Off-State Leakage Current (60Hz)
1
mA
Turn-On Time (60Hz)
DRL48R35
DRL48D
DRL48A
0.1
ms
8.3
ms
24.9 ms
Turn-Off Time (60Hz)
DRL48R35
DRL48D
DRL48A
8.3
ms
8.3
ms
24.9 ms
Operating Frequency Range 0.1
Off-State dv/dt
I2t for match fusing (<8.3ms)
440
500
1500
Hz
V/µs
A2S
THERMAL CHARACTERISTICS
45
40
35
30
25
20
15
10
5
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (°C)
Figure 4 — DRL relays
SURGE CURRENTS
600
Non-Repetitive
400
200
Repetitive with initial Tj = 70˚C
0
0.01
0.1
1
10
t (s)
Figure 5 — DRL relays
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
DRL 3
DRL\032003\Q1