English
Language : 

DRL48R35 Datasheet, PDF (1/4 Pages) Teledyne Technologies Incorporated – Single Output to 35A 510 Vac DIN-Rail Solid-State Relay
Part Number
DRL48R35
DRL48D35-21
DRL48D35
DRL48A35-22
DRL48A35
Description
35A 510 Vac Output
35A 480 Vac Output
35A 510 Vac Output
35A 510 Vac Output
35A 510 Vac Output
Part Number Explanation
DRL
48
D
35
-21
NOTES
1) Line Voltage (nominal): 48 = 480 Vac
2) Switch Type: D = Zero-cross turn-on; A = Zero-cross, AC control;
R = Random turn-on
3) Features: -21 = Self turn-on suppression; -22 = 24 Vac control
MECHANICAL SPECIFICATION
NEW Series DRL
Single Output to 35A 510 Vac
DIN-Rail Solid-State Relay
FEATURES/BENEFITS
• Mounting and dismounting on DIN rail without
any tool or directly mountable on panel
• Zero-cross and random models; thyristors output
• Large control range
• Green control LED
• Very high immunity
• Low leakage current
• Internal transient suppression
DESCRIPTION
The Series DRL single-phase DIN-rail relays are
designed for all types of loads. The relays utilize
optical isolation to protect the control from load
transients. DRL relays have an integral heat sink, and
can be mounted and dismounted onto a DIN rail
without any tools. The relays may also be panel
mounted. All relays offer a green control LED and
transient suppression.
APPLICATIONS
• Heating control
• Motor control
• Industrial and process control
APPROVALS
Series DRL relays are pending UL recognition.
Figure 1 — DRL relay; dimensions in inches (mm)
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
DRL 1
DRL\032003\Q1