CONTROL CHARACTERISTIC
12
10
8
6
4
2
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
Control Voltage (V)
Figure 2a — DR38R and DR48D relays
20
15
10
5
0
0 10 20 30 40 50 60
Control Voltage (V)
Figure 2b — DRL48A35-22 relay
8
6
4
2
0
0
50
100 150 200 250
Control Voltage (V)
Figure 2c — DRL48A35 relay
Series DRL
INPUT (CONTROL) SPECIFICATION
Min
Max Units
Control Range
DRL48R35
3.5
32 Vdc
DRL48D35-21
3
32 Vdc
DRL48D35
3.5
32 Vdc
DRL48A35-22
17
60 Vac/Vdc
DRL48A35
150
240 Vac/Vdc
Control Current Range
DRL48R35
DRL48D
DRL48A35-22
3
DRL48A35
3
10 mAdc
10 mAdc
20
mA
7
mA
Must Turn-off Voltage
DRL48R35
2
V
DRL48D35-21
1
V
DRL48D35
2
V
DRL48A35-22
4
V
DRL48A35
15
V
Reverse Voltage (DC Control)
Clamping Voltage (DC Control)
Input LED
32
V
42
V
Green
TYPICAL APPLICATION
400 Vac 60Hz
400 Vac 60Hz
Protection
L1
SSR
Protection
L1
SSR
T1
A2 A1
–+
Control
Load
T1
A2 A1
Control
Load
Figure 3 — DRL relay DC control (left) and DRL relay
AC control (right)