English
Language : 

DRS24D25 Datasheet, PDF (2/4 Pages) Teledyne Technologies Incorporated – Single Output to 30A 510 Vac DIN-Rail Solid-State Relay with Diagnostics
Series DRS
INPUT (CONTROL) SPECIFICATION
Min
Max Units
Control Range
DRS24
3
32 Vdc
DRS48
3.5
32 Vdc
Control Current Range
10 mAdc
Must Turn-Off Voltage
2
Vdc
Reverse Voltage
32
V
Clamping Voltage
42
V
Input LED
Green
OUTPUT (LOAD) SPECIFICATION
Min
Max
Operating Range
DRS24
70
280
DRS48
150
510
Unit
Vrms
Vrms
Peak Voltage
1200 Vpeak
Clamping Voltage (@1mA)
DRS48
820
V
Load Current Range
DRSXXD25
DRS48D30
.1
25
A
.005
30
A
Zero-Cross Window (Typical)
±14
V
Motor Load
DRS48D30
All others
12 Arms
contact factory
Switch ON voltage in case of overvoltage
DRS24
950
V
Non-Repetitive Overload Current (See Figure 6)
DRSXXD25
550
A
DRS48D30
1000 A
On-State Voltage Drop (Typical)
DRSXXD25
DRS48D30
0.9
V
0.75
V
OUTPUT (LOAD) SPECIFICATION (Continued)
Min
Max Unit
Thermal Resistance
(Junction to Ambient)
3.3 (2.5) W
Off State Leakage Current (60Hz)
DRDXXD25
DRS48D30
5
mA
1
mA
Turn-On Time (60Hz)
Turn-Off Time (60Hz)
Operating Frequency Range 40
Off-State dv/dt
8.3
ms
8.3
ms
440 Hz
500 V/µs
I2t for match fusing (<8.3ms)
DRSXXD25
DRS48D30
1500 A2S
5000 A2S
CONTROL CHARACTERISTIC
12
10
8
6
4
2
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
Control Voltage (V)
Figure 3 — DRS relay
Ic A1
Control Vc
SCHEMATIC
Main
1 L1
Fuse
A2 LED
Id
Output
Status Vds
LED
Load
2 T1
Figure 4 — DRS relay
DRS 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
DRS\032003\Q1