English
Language : 

408-10389 Datasheet, PDF (6/19 Pages) TE Connectivity Ltd – Ocean Side-Feed Applicators
408-10389
The servo feed applicator works in conjunction with the AMPOMATOR III servo terminator (or any machine
utilizing the TE precision controller) to form a complete system that allows setup and operation. Information on
the data chip is listed in three separate groups: applicator data, terminal data, and maintenance data.
A significant amount of the data is reference data to aid in machine setup and final crimp inspection.
2.4. Applicator with Non-Servo Feed System
As with the data chip on the servo feed latch plate, optional data chip kit PN 2161326-[ ] also allows storage for
key operating parameters and contains reference data useful in setting up the machine and crimp inspection. It
requires compatible terminating equipment. For complete description of the data chip, refer to 409–10073.
2.5. Applicator with Non-Adjust Head
With this applicator, all wire crimp height adjustments are made by the machine. When built in the factory, the
applicator's non-adjust head is shimmed so that the applicator will crimp its assigned terminal to the largest
wire crimp height found on the applicator log while the terminating machine is set to normal shut height.
NOTE
If using an applicator with a fine-adjust head on a machine with a self-adjusting wire crimp height feature, always set the
fine-adjust head to the largest wire crimp height called out on the applicator log.
2.6. Applicator with Pacific Head
The Pacific applicator will work only when used with a machine having a ram that falls within the envelope
shown in Figure 7.
Note: Dimensions are in millimeters
with inches in brackets.
13.50 [.531]
Min
16.70 [.657]
Min
ø20.40 [.803]
Max
ø27.70 [1.091] Max
ø41.90 [1.650] Max
Figure 7
7.99 [.315] Min
4.50 [.177] Max
3. APPLICATOR INSTALLATION AND REMOVAL
DANGER
To avoid personal injury, make sure that the power and air source to the machine is turned off and power cord/air supply are
disconnected before installing or removing the applicator.
NOTE
Always make sure to remove the ram transportation collar after installing the applicator on a machine and be sure to install the
ram transportation collar back onto the applicator ram just prior to removing the applicator from the machine.
NOTE
With the applicator in the machine, never attempt to cycle machine under power without terminals properly loaded, as
described in Section 4; otherwise, the tooling may be damaged.
DANGER
To avoid personal injury, the applicator should be used only in an appropriate terminating machine. The pressurized air supply
should only be connected after the applicator is properly installed in the terminating machine.
Rev M2