108-2375 Datasheet, PDF (6/10 Pages) TE Connectivity Ltd – STRADA Mesa* High Speed Mezzanine Press-Fit Differential Connector System
108-2375
Thermal shock.
See Note.
EIA-364-32, Test Condition VII.
Subject mated specimens to 5
cycles between -55 and 105°C.
Temperature transfer rate shall be <
1 minute with 30 minute dwell at
each temperature extreme.
Thermal disturbance.
See Note.
Subject mated specimens to 10
cycles between 15 and 85°C.
Temperature ramp shall be a
minimum of 2°C per minute with 5
minutes minimum dwell at
temperature extremes.
Mixed flowing gas, 14 days.
See Note.
EIA-364-65, Class IIA (4 gas).
Subject mounted specimens to
environmental Class IIA for 14
days. Ten days unmated, 4 days
mated.
Mixed flowing gas, 20 days.
See Note.
EIA-364-65, Class IIA (4 gas).
Subject mounted specimens to
environmental Class IIA for 20
days. Ten days unmated, 10 days
mated.
Dust.
See Note.
EIA-364-91.
Subject unmated receptacle
specimens to dust exposure for 1
hour at a flow rate of 300 cfm. Dust
composition shall be #1 Benign.
Use 9 grams of dust for each cubic
foot of chamber space. Dry dust for
1 hour at 50°C prior to application
to connector. After exposure, let
specimens sit for 1 hour in
chamber.
Figure 2 (end)
NOTE
Shall meet visual requirements, show no physical damage, and meet requirements of
additional tests as specified in the Product Qualification and Requalification Test Sequence
shown in Figure 3.
Rev C
6 of 10