English
Language : 

108-2375 Datasheet, PDF (5/10 Pages) TE Connectivity Ltd – STRADA Mesa* High Speed Mezzanine Press-Fit Differential Connector System
Durability, 25 cycles.
Durability, 20 cycles.
Durability, 250 cycles.
Mating force.
Unmating force
Disturbed interface.
Reseating.
Humidity/temperature cycling.
High temperature life, 105°C.
High temperature life, 105°C.
108-2375
See Note.
EIA-364-9.
Mate and unmate specimens for 25
cycles at a maximum rate of 500
cycles per hour. The first 13 cycles
shall be performed prior to specific
environmental test in the sequence.
The remaining 12 cycles shall be
performed after environmental test.
The test shall be performed with
header and receptacle installed
(press-fit) on test boards.
See Note.
EIA-364-9.
Mate and unmate specimens for 20
cycles at a maximum rate of 500
cycles per hour.
See Note.
EIA-364-9.
Mate and unmate specimens for
250 cycles at a maximum rate of
500 cycles per hour.
45 grams-force maximum for signal EIA-364-13.
contacts.
Measure force necessary to mate
1200 grams-force maximum for specimens at a rate of 12.7 to 25.4
power contacts.
mm per minute.
5 grams-force minimum for signal
contacts.
120 grams-force minimum for
power contacts.
EIA-364-13.
Measure force necessary to unmate
specimens at a rate of 12.7 to 25.4
mm per minute.
See Note.
Interface shall be disturbed so that
contact surfaces move about 0.10
mm or less.
See Note.
Unmate and remate specimens 3
times.
ENVIRONMENTAL
See Note.
Telcordia GR-1217 (Central Office).
Subject mated specimens to 50
cycles (500 hours) between 25 and
65°C at 90 to 98% RH.
Temperature ramp shall be 2 hours
per transition with 4 hours dwell at
65°C and 2 hours dwell at 25°C (10
hours total per cycle).
See Note.
EIA-364-17, Method A, Test
Condition 4.
Subject mated specimens to 105°C
for 120 hours.
See Note.
EIA-364-17, Method A, Test
Condition 4, Test Time Condition C.
Subject mated specimens to 105°C
for 500 hours.
Figure 2 (continued)
Rev C