108-2086 Datasheet, PDF (6/6 Pages) TE Connectivity Ltd – When tests are performed on the subject product line, procedures specified in Figure 1 shall be used.
108-2086
.250 Series:
Wire Size
Wire Dia. (mm)
0.60
0.85
1.00
1.10
CMA
Current ( amperes)
Copper
566
2.6
1120
4
1550
6.1
1875
8.1
Tensile N (lbf)
Copper
30 (6.5)
59 (13)
83 (18.8)
116 (26)
NOTE
NOTE
1. CMA values are based on standard magnet wire with single film coating.
2. Current values for standard copper wire gages are from UL 310, others are
rated based on their respective CMA.
3. Current values for aluminum wires are 64.5% of the copper wire of equivalent
gage.
4. Tensile values are calculated at 50% of the bare wire tensile.
Figure 4
Current Carrying/Tensile Capability
Figure 5
Vibration and Mechanical Shock Mounting Fixture
Rev F