English
Language : 

408-9010 Datasheet, PDF (4/4 Pages) TE Connectivity Ltd – Shielding Hardware Kits with AMPLIMITE
Hinge
Tabs
Outer Shield
408- 9010
2. Crimp the ferrule onto the shield assembly and
cable.
3. Examine the terminated assembly according to
Figure 8 and, if necessary, trim excess cable braid
from the braid crimp area.
Terminated Length
Connector
Figure 6
Inner Shield
Outer
Shield
Latching Tab
(Engaged)
Cable
Jacket
Ferrule
Inner
Shield
Figure 7
Braid Crimp
Area
Excess Cable Braid
Trimmed
Crimped
Ferrule
CONNECTOR
TYPE
HDE--20
HDP--20
HDP--22
CONTACT
POSITION
9, 15, 25
37
9, 15, 25
37
50
15, 26, 44
62
78
Figure 8
TERMINATED LENGTH
+.635 [.025] (mm [in.])
38.61 [1.520]
47.42 [1.867]
38.99 [1.535]
48.06 [1.892]
47.65 [1.876]
38.99 [1.535]
48.06 [1.892]
47.65 [1.876]
5. CRIMPING THE FERRULE
1. Refer to Figure 1 and determine the crimping
die assembly and tooling to be used for crimping
the ferrule.
6. REVISION SUMMARY
Revisions to this instruction sheet include:
S Updated to corporate requirements.
4 of 4
Rev C