408-9010 Datasheet, PDF (2/4 Pages) TE Connectivity Ltd – Shielding Hardware Kits with AMPLIMITE
408- 9010
CONTACT POSITION
HDE- 20, HDP- 20
HDP- 22
FERRULEH
747579--8
9, 15, 25
15, 26, 44
1--747579--0
1--747579--1
1--747579--2
1--747579--4
37
62
747580--6
1--747580--0
37, 50
747580--8
78
747580--4
747580--5
H Must be ordered separately from shielding hardware kit.
S Instruction material shown in parenthesis.
CABLE DIAMETER
RANGE (mm [in.])
4.19--4.83 [.165--.190]
4.83--5.51 [.190--.217]
5.51--6.25 [.217--.246]
6.25--7.21 [.246--.284]
7.21--8.23 [.284--.324]
8.23--9.52 [.324--.375]
9.52--11.05 [.375--.435]
10.16--11.56 [.400--.455]
12.19--14.28 [.480--.562]
5.84--6.73 [.230--.265]
8.58--9.78 [.338--.385]
9.52--10.97 [.375--.432]
10.72--12.45 [.422--.490]
Figure 2
CRIMPING DIE
ASSEMBLYS
543424--3 (408--9507)
543424--2 (408--9507)
543424--8 (408--9507)
543424--1 (408--9507)
543424--7 (408--9507)
543424--6 (408--9507)
543424--5 (408--9507)
543424--4 (408--9507)
58237--1 (408--9242)
543425--2 (408--9508)
543425--1 (408--9508)
58238--1 (408--9243)
58237--2 (408--9242)
TOOLINGS
Hand Crimping
Tool 543344--1
(408--9315)
or
2700--lb
Pneumatic Power
Unit 312522--3
(409--5843)
fitted with
Die Holder
58449--1
(408--9721)
3. PREPARATION
The contacts will accept solid or stranded wire with an
individual wire size range of 28 through 18 AWG.
Prepare the cable as follows:
1. Obtain the connector and cable of the type and
size required for your application. See Figure 2.
2. Slide the appropriate ferrule, smaller diameter
end first, onto the cable. See Figure 3.
CAUTION
!
The ferrule MUST be placed on the cable before
terminating the connector and installing the metal
shields. The metal shields cannot be crimped
onto the cable without using a ferrule.
3. Strip the jacket to dimension shown in Figure 3.
Then fold braid back over cable jacket.
NOTE
i
Braid may be trimmed to 12.7 mm [.50 in.] now,
or trimmed after ferrule crimping.
4. Terminate individual wires onto connector
contacts.
NOTE
i
For information regarding wire termination of
AMPLIMITE HDE- 20 connectors, refer to
Instruction Sheet 408- 6645; for AMPLIMITE
HDP- 20 connectors, refer to 408- 7514; and for
AMPLIMITE HDP- 22 connectors, refer to
408- 9381.
Note: Note to Scale
Strip Cable Jacket
Ferrule
(Typ)
Braid May Be Trimmed to
12.7 mm [.50 in.]
Individual Wires
CONTACT POSITION
HDE- 20, HDP- 20
HDP- 22
9, 15, 25
37
50
15, 26, 44
62
78
Figure 3
CABLE JACKET
STRIP LENGTH
+1.27 [.050] (mm [in.])
33.02 [1.300.]
43.18 [1.700]
40.64 [1.600]
2 of 4
Rev C