S it should have flat surfaces with holes or a
channel large enough and deep enough to
receive any protruding components of the
connector and cage assembly and to prevent
the pc board from bowing.
3.2. Application Tool
Power for seating tools must be provided by an
application tool (with a ram) capable of supplying a
downward force of 44.5 N [10 lb--force] per contact.
Manual Arbor Frame Assembly 58024--1 is available
for use with these seating tool kits. Refer to
Instruction Sheet 408--6923 for operating procedure.
CAUTION
!
Over- driving of the connector and cage assembly
will deform parts critical to the quality of the
connection. Maximum force occurs prior to the
connector and cage assembly bottoming on the
pc board.
4. SETUP
When setting up equipment to seat the connector and
cage assembly, pay particular attention to the
following:
S the seating tool must be matched to the
connector and cage assembly
CAUTION
!
If the seating tool and connector and cage
assembly are mismatched or are improperly
aligned, damage could occur to the tooling,
connector and cage assembly, or both.
S the wall support must be properly installed, and
the seating tool, connector and cage assembly,
and application tool ram must be properly
aligned before cycling the application tool
1. Set tool seating height to the dimension shown
in Figure 2 (application tool shut height will equal
the tool seating height PLUS the combined
thicknesses of the pc board and support fixture).
After seating, a gap of no more than 0.10 mm
[.004 in.] between the cage assembly standoffs
and the pc board is allowed.
NOTE
i
Use the tool seating height as a reference
starting point. This height may need to be
adjusted to obtain the amount allowed (maximum
of 0.10 mm [.004 in.]) between the standoffs of
the cage assembly and the pc board.
2. Slide the wall support into the port(s) of the cage
assembly until the wall support is secure.
5. SEATING (Figure 2)
1. Place the pc board on the support fixture.
2. Orient the seating tool over the cage assembly
so that the back is aligned with the back of the
cage assembly. Then lower the seating tool onto
the cage assembly, making sure that the cutouts
slide over the protruding components of the cage
assembly, until the seating tool bottoms on the top
of the cage assembly.
Note: Not to Scale
A
(See Table)
Application Tool
Shut Height
(Ram Fully Down)
(See Section 4, Step 1)
B
(See Table)
0.10 mm [.004 in.]
(Max) Gap Allowed
Ram of Application Tool
(Fully Down)
Seating Tool (2018280- 1 Shown)
Cage Assembly
Wall Support (Installed in
Ports of Cage Assembly)
Press- Fit Contacts (and Any
Protruding Components) Inserted
into Holes in PC Board and
PC Board Support Fixture
DIMENSION A
TOOL SEATING HEIGHTD
40.64 mm [1.60 in.]
D With Connector and Cage Assembly Seated
PC Board
PC Board Support Fixture
DIMENSION B
CAGE ASSEMBLY SEATING HEIGHTD
25.5 mm [1.004 in.]
Figure 2
2 of 4
Rev C