B722*
Test
Vibration
Bump
Fire hazard
Test methods/conditions
IEC 60068-2-6, test Fc, method B4
Frequency range: 10 … 55 Hz
Amplitude:
0.75 mm or 98 m/s2
Duration:
6 h (3 · 2 h)
Pulse:
sine wave
After repeatedly applying a single
harmonic vibration according to the
table above.
The change of VV shall be measured
and the specimen shall be visually
examined.
IEC 60068-2-29, test Eb
Pulse duration: 6 ms
Max. acceleration: 400 m/s2
Number of bumps:4000
Pulse:
half sine
IEC 60695-11-5 (needle flame test)
Severity: vertical 10 s
Requirement
|∆V/V (1 mA)| ≤5%
No visible damage
|∆V/V (1 mA)| ≤5%
No visible damage
5 s max.
Note:
UCT = Upper category temperature
LCT = Lower category temperature
Rins = Insulation resistance
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 22