S10K300E2K1 Datasheet, PDF (5/22 Pages) TDK Electronics – SIOV metal oxide varistors
Leaded varistors
AdvanceD-MP, S10 series
B722*
Reliability data
Test
Varistor voltage
Clamping voltage
Endurance at upper
category temperature
Surge current derating,
8/20 µs
Surge current derating,
2 ms
Electric strength
Test methods/conditions
Requirement
The voltage between two terminals with To meet the specified value
the specified measuring current applied
is called VV (1 mADC @ 0.2 ... 2 s).
The maximum voltage between two To meet the specified value
terminals with the specified standard
impulse current (8/20 µs) applied.
1000 h at UCT
|∆V/V (1 mA)| ≤10%
After having continuously applied the
maximum allowable AC voltage at UCT
±2 °C for 1000 h, the specimen shall be
stored at room temperature and normal
humidity for 1 to 2 h.
Thereafter, the change of VV shall be
measured.
10 surge currents (8/20 µs), unipolar, |∆V/V (1 mA)| ≤10%
interval 30 s, amplitude corresponding (measured in direction of
to derating curve for 10 impulses at
20 µs
surge current)
No visible damage
10 surge currents (2 ms), unipolar,
|∆V/V (1 mA)| ≤10%
interval 120 s, amplitude corresponding (measured in direction of
to derating curve for 10 impulses at
surge current)
2 ms
No visible damage
IEC 61051-1, test 4.9.2
No breakdown
Metal balls method, 2500 VRMS, 60 s
The varistor is placed in a container
holding 1.6 ±0.2 mm diameter metal
balls such that only the terminations of
the varistor are protruding.
The specified voltage shall be applied
between both terminals of the specimen
connected together and the electrode
inserted between the metal balls.