English
Language : 

NRH2410TR68NN4 Datasheet, PDF (11/12 Pages) Taiyo Yuden (U.S.A.), Inc – SMD INDUCTORS SMALL AND LARGE CURRENT TYPE
˙ RELIABILITY DATA
18. Loading under damp heat
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
Inductance change : Within ʶ10%
No significant abnormality in appearance.
NR10050 Type
ʲTest Method and Remarksʳ
BRC1608, BRL2012, BRC2016, BRC2518, BRFL2518, BRL2518, BRL3225 Type :
Temperature
Humidity
Applied current
Time
60ʶ2ˆ
90ʙ95ˋRH
Rated current
1000hours.
Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
NR30/40/50/60/80, NRV30, NRG40, NRH24/30, NRS50/60 Type, NR10050 Type :
The test samples shall be soldered to the test board by the reflow.
The test samples shall be placed in thermostatic oven set at specified temperature and humidity and applied the rated current continuously as shown in below table.
Temperature
Humidity
Applied current
Time
60ʶ2ˆ
90ʙ95ˋRH
Rated current
500ʶ2hour
19. Low temperature life test
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
Inductance change : Within ʶ10%
No significant abnormality in appearance.
NR10050 Type
ʲTest Method and Remarksʳ
BRC1608, BRL2012, BRC2016, BRC2518, BRFL2518, BRL2518, BRL3225 Type :
Temperature
Duration
ʔ40ʶ2ˆ
1000hours
Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
NR30/40/50/60/80, NRV30, NRG40, NRH24/30, NRS50/60 Type, NR10050 Type :
The test samples shall be soldered to the test board by the reflow.
After that, the test samples shall be placed at test conditions as shown in below table.
Temperature
Time
ʵ40ʶ3ˆ
500ʶ24hour
20. High temperature life test
BRC1608, BRL2012, BRC2016, BRC2518, Inductance change : Within ʶ10%
BRFL2518, BRL2518, BRL3225 Type
No significant abnormality in appearance.
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
NR10050 Type
Inductance change : Within ʶ10%
No significant abnormality in appearance.
ʲTest Method and Remarksʳ
BRC1608, BRL2012, BRC2016, BRC2518, BRFL2518, BRL2518, BRL3225 Type :
Temperature
Duration
85ʶ2ˆ
1000hours
Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
NR10050 Type :
Temperature
Time
105ʶ3ˆ
500ʶ24hour
Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
21. Loading at high temperature life test
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
Inductance change : Within ʶ10%
No significant abnormality in appearance.
NR10050 Type
ʲTest Method and Remarksʳ
NR30/40/50/60/80, NRV30, NRG40, NRH24/30, NRS50/60 Type :
The test samples shall be soldered to the test board by the reflow soldering.
Temperature
Applied current
Time
85ʶ2ˆ
Rated current
500ʶ24hour
22. Standard condition
BRC1608, BRL2012, BRC2016, BRC2518, Standard test condition :
BRFL2518, BRL2518, BRL3225 Type
Unless otherwise specified, temperature is 20ʶ15ˋ and 65ʶ20ˋof relative humidity.
NR30/40/50/60/80, NRV30, NRG40,
When there are question concerning measurement result : In order to provide correlation date, the test shall be condition of 20ʶ2ˆ
NRH24/30, NRS50/60 Type
of temperature, 65ʶ5% relative humidity.
NR10050 Type
Inductance is in accordance with our measured value.
ˎ This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
wound0407_reli_e-01

wound0407_reli-RP4