English
Language : 

MPFC-115-270-QP Datasheet, PDF (7/16 Pages) SynQor Worldwide Headquarters – Internal inrush current limit
Screening & Qualification Testing
MPFC-115-270-QP
Input:85-180Vrms
Output:270Vdc
Power:350W
Mil-COTS Qualification
Test Name
Life Testing
Details
Visual, mechanical and electrical testing before, during and after 1000 hour burn-in
@ full load
# Tested
(# Failed)
15
(0)
Consistent with
MIL-STD-883F Method
Method 1005.8
Shock-Vibration
Visual, mechanical and electrical testing before, during and after shock and
vibration tests
5
MIL-STD-202,
(0)
Methods 201A & 213B
Humidity
+85˚C, 95% RH, 1000 hours, 2 minutes on / 6 hours off
8
(0)
Method 1004.7
Temperature
Cycling
Solderability
500 cycles of -55˚C to +100˚C
(30 minute dwell at each temperature)
15 pins
10
(0)
Method 1010.8, Condition A
15
(0)
Method 2003
DMT
-65˚C to +110˚C across full line and load specifications in 5˚C steps
7
(0)
Altitude
70,000 feet (21 km), see Note
2
(0)
Note: A conductive cooling design is generally needed for high altitude applications because of naturally poor convective cooling at rare atmospheres.
Screening
Baseplate Operating Temperature
Storage Temperature
Pre-Cap Inspection
Temperature Cycling
Burn-In
Final Electrical Test
Final Visual Inspection
Mil-COTS Converter and Filter Screening
Process Description
S-Grade
-55˚C to +100˚C
IPC-A-610, Class III
-65˚C to +135˚C
●
MIL-STD-883F, Method 1010, Condition B, 10 Cycles
100˚C Baseplate
100%
MIL-STD-883F, Method 2009
12 Hours
25˚C
●
M-Grade
-55˚C to +100˚C
-65˚C to +135˚C
●
●
96 Hours
-55˚C, +25˚C, +100˚C
●
MIL-STD-810G Test
Fungus
Altitude
Rapid Decompression
Acceleration
Salt Fog
High Temperature
Low Temperature
Temperature Shock
Rain
Immersion
Humidity
Random Vibration
Shock
Sinusoidal vibration
Sand and Dust
Method
Mil-COTS MIL-STD-810G Qualification Testing
Description
508.6
Table 508.6-I
500.5 - Procedure I
Storage: 70,000 ft / 2 hr duration
500.5 - Procedure II Operating: 70,000 ft / 2 hr duration; Ambient Temperature
500.5 - Procedure III Storage: 8,000 ft to 40,000 ft
513.6 - Procedure II Operating: 15 g
509.5
Storage
501.5 - Procedure I
Storage: 135°C / 3 hrs
501.5 - Procedure II Operating: 100°C / 3 hrs
502.5 - Procedure I
Storage: -65°C / 4 hrs
502.5 - Procedure II Operating: -55°C / 3 hrs
503.5 - Procedure I - C Storage: -65°C to 135°C; 12 cycles
506.5 - Procedure I
Wind Blown Rain
512.5 - Procedure I
Non-Operating
507.5 - Procedure II Aggravated cycle @ 95% RH (Figure 507.5-7 aggravated temp - humidity cycle, 15 cycles)
514.6 - Procedure I
10 - 2000 Hz, PSD level of 1.5 g2/Hz (54.6 grms), duration = 1 hr/axis
516.6 - Procedure I
20 g peak, 11 ms, Functional Shock (Operating no load) (saw tooth)
516.6 - Procedure VI Bench Handling Shock
514.6 - Category 14
Rotary wing aircraft - helicopter, 4 hrs/axis, 20 g (sine sweep from 10 - 500 Hz)
510.5 - Procedure I
Blowing Dust
510.5 - Procedure II Blowing Sand
Product # MPFC-115-270-QP
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0006727 Rev. B 03/31/2016
Page 7