English
Language : 

MPFC-115-270-QP Datasheet, PDF (5/16 Pages) SynQor Worldwide Headquarters – Internal inrush current limit
Technical Diagrams
MPFC-115-270-QP
Input:85-180Vrms
Output:270Vdc
Power:350W
98.00
96.00
94.00
92.00
90.00
88.00
86.00
84.00
0
140Vrms
115Vrms
90Vrms
50
100
150
200
250
300
350
Output Power (W)
Figure 1: Efficiency at nominal output voltage vs. load power for 90Vrms,
115Vrms and 140Vrms (60Hz) input voltage at Tb = 25°C.
30
90Vrms
25
115Vrms
140Vrms
20
15
10
5
0
0
50
100
150
200
250
300
350
Output Power (W)
Figure 2: Power dissipation at nominal output voltage vs. load power for 90Vrms,
115Vrms and 140Vrms (60Hz) input voltage at Tb = 25°C.
Figure 3: Typical Input Voltage and Current waveforms at full rated power
(115Vrms, 60Hz) Top: Vin (100V/div), Bottom: Iin (5A/div), Timebase: (5ms/div).
Figure 4: Typical Input Voltage and Current waveforms at full rated power
(115Vrms, 400Hz). Top: Vin (100V/div), Bottom: Iin (5A/div), Timebase: (1ms/
div).
350
115Vrms, 400Hz
300
115Vrms, 60Hz
250
200
150
100
50
0
1 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.91 0.9
Leading Power Factor
310
305
300
295
290
285
280
275
270
265
260
255
250
245
85
Max
Typical
Min
95 105 115 125 135 145 155 165 175
Input Voltage (Vrms)
Figure 5: Output power vs. leading power factor, MPFC module only
Figure 6: DC output voltage range vs. input voltage
Product # MPFC-115-270-QP
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0006727 Rev. B 03/31/2016
Page 5