English
Language : 

PQ60150EKXXX Datasheet, PDF (5/15 Pages) SynQor Worldwide Headquarters – Thermal shutdown protects converter from abnormal environmental conditions
Technical Specification
Input: 35-75V
Output: 15V
Current: 3.3A
Part No.: PQ60150EKx03
PQ60150EKx03Electrical Characteristics (Continued)
Ta=25°C, airflow rate=300LFM, Vin=48V dc unless otherwise noted; full operating temperature range is -40°C to +100°C baseplate temperature with
appropriate power derating. Specifications subject to change without notice.
Parameter
Min. Typ. Max. Units Notes & Conditions
DYNAMIC CHARACTERISTICS
Input Voltage Ripple Rejection
55
dB 120Hz
Output Voltage during Load Current Transient
See Note 3
Step Change in Output Current (0.1A/µs)
320
mV 50% to 75% to 50% Iout max; Figure 11
Step Change in Output Current (1A/µs)
130
mV 50% to 75% to 50% Iout max; Figure 12
Settling time
150
µs To within 1% Vout nom
Turn-On Transient
Turn-On Time
25
ms Full load, Vout=90% nom; Figures 9 & 10
Start-Up Inhibit Time
180
200
240
ms -40°C to 125°C; Figure F
Output Voltage Overshoot
0
% Maximum Output Capacitance,Iout=0A
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
2000
V See Absolute Maximum Ratings
Isolation Resistance
30
MΩ
Isolation Capacitance (input to output)
1000
pF See Note 4
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
125
°C Package rated to 150°C
Board Temperature
125
°C UL rated max operating temp 130°C
Transformer Temperature
125
°C
FEATURE CHARACTERISTICS
Switching Frequency
360
400
440
kHz
ON/OFF Control (Option P)
Off-State Voltage
0
0.8
V
On-State Voltage
2
13.5
V
ON/OFF Control (Option N)
Off-State Voltage
2
13.5
V
On-State Voltage
0
0.8
V
ON/OFF Control (Either Option)
Application notes; Figures A & B
Pull-Up Voltage
5
6
V
Pull-Up Resistance
10
kΩ
Output Voltage Trim Range
-10
10
% Measured across Pins 8 & 4; Figure C
Output Voltage Remote Sense Range
10
% Measured across Pins 8 & 4
Output Over-Voltage Protection
125
% Full Load; % of nominal Vout
Over-Temperature Shutdown
125
°C Average PCB Temperature
Over-Temperature Shutdown Restart Hysteresis
10
°C
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
2.5
106 Hrs. TR-NWT-000332; 80% load, 300LFM, 40°C Ta
1.1
106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40°C Ta
106 Hrs. See our website for details
Note 1: The UVLO values represented here are typical of lighter load conditions. The unit may shut down under high load conditions before the typical
UVLO limits.
Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 3: The module requires a minimum amount of capacitance (100μF) in order to ride through a No Load to Full Load transient (0.1A/μs) without
shutdown.
Note 4: Higher values of isolation capacitance can be added external to the module.
Product # PQ60150EKx03
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005265 Rev. A
08/20/09
Page 5