English
Language : 

BQ4H136EEC45 Datasheet, PDF (5/13 Pages) SynQor Worldwide Headquarters – Industry standard eighth-brick pin-out configuration
Technical Specification
Input: 230-400 V
Output: 13.6 V
Current: 45 A
Package: EXTENDED Eighth-brick
Compliance & Testing
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1:2007/R:2011-12
Basic insulation
EN 60950-1:2006/A2:2013
CAN/CSA C22.2 No. 60950-1:2007/A1:2011
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units Test Conditions
32
5
5
10
5
5
5
15 pins
95% rated Vin and load, units at derating point, 1000 hours
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100 g minimum, 2 drops in x, y and z axis
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day
MIL-STD-883, method 2003
Product # BQ4H136EEC45
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0006641 Rev. C
05/11/16
Page 5