English
Language : 

PQ60025QPA60 Datasheet, PDF (4/14 Pages) SynQor Worldwide Headquarters – Quarter-brick DC/DC Converter
Technical Specification
Input: 35-75 V
Output: 2.5 V
Current: 60 A
Package: Quarter-brick
ELECTRICAL CHARACTERISTICS (Continued)
Parameter P
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control (Option P)
Off-State Voltage
On-State Voltage
ON/OFF Control (Option N)
Off-State Voltage
On-State Voltage
ON/OFF Control (Either Option)
Pull-Up Voltage
Pull-Up Resistance
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
Load Current Scale Factor
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
Min.
250
-2
2.4
2.4
-2
-20
117
Typ.
270
Vin/6.5
40
122
125
10
1714
2.37
1.75
Max. Units Notes & Conditions
290
kHz Regulation stage and Isolation stage
0.8
V
18
V
18
0.8
9.2
+10
+10
127
V
V
Figures A, B
V
kΩ
%
Measured across Pins 9 & 5; Figure C; See Figure 27 & 28
%
Measured across Pins 9 & 5; See Figure 27 & 28
% Over full temp range; % of nominal Vout
°C Average PCB Temperature
°C
See App Note: Output Load Current Calc.
106 Hrs.
106 Hrs.
106 Hrs.
TMSReI-LeN-HW wDeBTb-K0s-0i2t0e137fo3Fr;2;9la39te%3s%tlovlaoadalu,de,2s20000LLFFMM,,4400ooCCTTaa
STANDARDS COMPLIANCE
Parameter P
STANDARDS COMPLIANCE
UL/cUL 60950
EN60950
72/23/EEC
93/68/EEC
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Telcordia (Bellcore) GR-513
Notes
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP (Normal Performance)
Section 7 - electrical safety, Section 9 - bonding/grounding
• An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety
certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter P
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units Test Conditions
32
5
5
10
5
5
5
15 pins
95% rated Vin and load, units at derating point, 1000 hours
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact factory for official product family qualification document.
OPTIONS
SynQor provides various options for Logic Sense, Pin Length and
Feature Set for this family of DC/DC converters. Please consult the
last page of this specification sheet for information on available
options.
PATENTS
SynQor is protected under various patents, including but not lim-
ited to U.S. Patent numbers: 5,999,417; 6,222,742 B1;
6,594,159 B2; 6,545,890 B2.
Product # PQ60025QPA60
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2QP625F Rev. A 12/10/04
Page 4