English
Language : 

RHFLVDS2281 Datasheet, PDF (6/17 Pages) STMicroelectronics – Rad-hard, dual 4x4 crosspoint switch LVDS
Maximum ratings and operating conditions
RHFLVDS2281
3
Maximum ratings and operating conditions
Absolute maximum ratings are those values beyond which damage to the device may occur.
Functional operation under these conditions is not implied.
Table 4. Absolute maximum ratings
Symbol
Parameter
Value
Unit
VCC
Vi
VOUT
VCM
Tstg
Tj
Rthjc
ESD
Supply voltage(1)
TTL inputs (operating or cold-spare)
LVDS outputs (operating or coldspare)
LVDS common mode (operating or cold-spare)
Storage temperature range
Maximum junction temperature
Thermal resistance junction to case(2)
HBM: Human body model
– All pins excepted LVDS inputs and outputs
– LVDS inputs and outputs vs. GND
4.8
-0.3 to +4.8
-0.3 to +4.8
-5 to +6
-65 to +150
+150
20
2
8
V
°C
°C/W
kV
CDM: Charge device model
500
V
1. All voltages, except the differential I/O bus voltage, are with respect to the network ground terminal.
2. Short-circuits can cause excessive heating. Destructive dissipation can result from short-circuits on the
amplifiers.
Symbol
VCC
VCM
TA
Table 5. Operating conditions
Parameter
Min.
Typ.
Supply voltage
3
3.3
Static common mode
-4
Ambient temperature range
-55
Max.
Unit
3.6
V
+5
+125
°C
6/17
DocID027588 Rev 1