English
Language : 

LSM303DLHCTR Datasheet, PDF (35/42 Pages) STMicroelectronics – Ultra compact high performance e-compass 3D accelerometer and 3D magnetometer module
LSM303DLHC
Table 61.
Z
Y
X
CLICK_SRC_A description (continued)
Z CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: Z high event has occurred)
Y CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: Y high event has occurred)
X CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: X high event has occurred)
7.1.24 CLICK_THS_A (3Ah)
Table 62. CLICK_THS_A register
--
Ths6
Ths5
Ths4
Ths3
Ths2
Register description
Ths1
Ths0
Table 63. CLICK_SRC_A description
Ths6-Ths0
CLICK-CLICK threshold. Default value: 000 0000
7.1.25
1 LSB = full-scale / 128. THS6 through THS0 define the threshold which is used by the
system to start the click detection procedure. The threshold value is expressed over 7 bits
as an unsigned number.
TIME_LIMIT_A (3Bh)
Table 64. TIME_LIMIT_A register
--
TLI6
TLI5
TLI4
TLI3
TLI2
TLI1
TLI0
Table 65. TIME_LIMIT_A description
TLI7-TLI0
CLICK-CLICK time limit. Default value: 000 0000
7.1.26
1 LSB = 1/ODR. TLI7 through TLI0 define the maximum time interval that can elapse
between the start of the click detection procedure (the acceleration on the selected channel
exceeds the programmed threshold) and when the acceleration goes back below the
threshold.
TIME_LATENCY_A (3Ch)
Table 66. TIME_LATENCY_A register
TLA7
TLA6
TLA5
TLA4
TLA3
TLA2
TLA1
TLA0
Table 67. TIME_LATENCY_A description
TLA7-TLA0
CLICK-CLICK time latency. Default value: 000 0000
Doc ID 018771 Rev 1