English
Language : 

LPS25HB Datasheet, PDF (35/40 Pages) STMicroelectronics – MEMS pressure sensor: 260-1260 hPa absolute digital output barometer
LPS25HB
8.17
TEMP_OUT_H (2Ch)
Temperature output value (MSB)
15
TOUT15
14
TOUT14
13
TOUT13
12
TOUT12
11
TOUT11
Register description
10
TOUT10
9
TOUT9
8
TOUT8
TOUT[15:8] This register contains the high part of the temperature output value.
The temperature output value is a 16-bit data that contains the measured temperature. It is
composed by TEMP_OUT_H (2Ch) and TEMP_OUT_L (2Bh). The value is expressed as
2’s complement.
8.18
FIFO_CTRL (2Eh)
FIFO control
7
F_MODE2
6
F_MODE1
5
4
3
2
1
0
F_MODE0 WTM_POINT4 WTM_POINT3 WTM_POINT2 WTM_POINT1 WTM_POINT0
F_MODE[2:0]
WTM_POINT[4:0]
FIFO mode selection. Default value: 000.
Refer to Table 21 and Section 4 for additional details.
FIFO threshold (watermark) level selection.
Refer to Table 22 for additional details.
Table 21. FIFO mode selection
F_MOD F_MODE F_MODE
0
0
0
Bypass mode
FIFO mode
0
0
1
FIFO mode
0
1
0
Stream mode
0
1
1
Stream-to-FIFO mode
1
0
0
Bypass-to-Stream mode
1
0
1
Not available
1
1
0
FIFO Mean mode
1
1
1
Bypass-to-FIFO mode
FIFO_MEAN mode: The FIFO can be used for implementing a HW moving average on the
pressure measurements. The number of samples of the moving average can be 2, 4, 8, 16
or 32 samples by selecting the watermark levels as per Table 22. Different configurations are
not allowed.
DocID027112 Rev 2
35/40
40