English
Language : 

LPS25HB Datasheet, PDF (17/40 Pages) STMicroelectronics – MEMS pressure sensor: 260-1260 hPa absolute digital output barometer
LPS25HB
5
Application hints
Application hints
Figure 5. LPS25HB electrical connections (top view)
VDD
GND
C1
GND
Pin indicator
10 9 8
Vdd_IO 1
7
SCL/SPC
2
6
345
INT_DRDY
CS
GND
The device power supply must be provided through the VDD line; the power supply
decoupling capacitor C1 (100 nF) must be placed as near as possible to the supply pads of
the device. Depending on the application, an additional capacitor of 4.7 µF could be placed
on VDD line.
The functionality of the device and the measured data outputs are selectable and accessible
through the I²C/SPI interface. When using the I²C, CS must be tied to Vdd_IO.
All the voltage and ground supplies must be present at the same time to have proper
behavior of the IC (refer to Figure 5.). It is possible to remove VDD while maintaining
Vdd_IO without blocking the communication bus, in this condition the measurement chain is
powered off.
5.1
Soldering information
The HLGA package is compliant with the ECOPACK® standard and it is qualified for
soldering heat resistance according to JEDEC J-STD-020.
DocID027112 Rev 2
17/40
40